Digital controller fx05 for opt dg 6, Air sensor 6, Compartment 6, 7 – Reznor SDH Parts Manuals User Manual
Page 6: Electronic filter 6, Plug-in cards 6, Ube holder 6, Enter speed controller 6, Electrical components (cont’d)

Form P-PREEVA, P/N 263985R7, Page 6
CODE 33 - Programmable Digital Controllers
CODE 35 - Outdoor
and Discharge
Air Sensor for
CODE 33,
P/N 206112
CODE 34 -
Plug-in Cards
for CODE 33
CODE 36 - Discharge Air Mixing Tube and
Sensor Holder with Electrical Box and
Cover, P/N 115850 (used with AG 3, 15, 16,
40, 60, 61, 62; DG 5, 6; D12 B, C, F, G)
Bracket,
P/N
213612, (not
illustrated) is
required if used
on indoor unit with
optional louvers
(See page 30.).
Electrical Components (cont’d)
For location of factory installed components, see page 3.
Electric Heat Section
Electrical Compartment -
Models PEH and REH
(See locations, page 7.)
FX05 in Control
Options DG1,
DG2, DG5, and
DG6
FX06 in Control
Options D12B,
D12C, D12F, and
D12G
CODE Description
PDH/SDH/RDH All Sizes
(applicable
options)
SHH/RHH
PXH/RXH
Secondary Panel in the Gas Heat Section Electrical Compartment (low voltage)
showing Digital Heating/Cooling Controls (PDH/SDH/SHH/RHH/RDH) or Main
Electrical Compartment (not shown) on Models PXH/RXH - See illustrations, page 3.
33
Digital Controller
FX05 Packaged Assembly (includes
controller and software for specific Option DG1, DG2,
DG5, or DG6)
Opt DG1
213635
Opt DG2
213636
Opt DG5
213637
Opt DG6
213638
Digital Controller
FX06 for D12B, D12C, D12F, D12G
(includes controller and software for specific Option
D12B, D12C, D12F, or D12G)
Replacing FX06 controller on units manufactured
prior to 12/2012 (Date Code BLL) requires a new
wiring harness; order P/N 270294.
Opt D12B
223485
Opt D12C
223486
Opt D12F
257432
Opt D12G
260087
Digital Controller
FX07 w/D12B software (special not illustrated)
262460
34
Plug-in Cards for
CODE 33:
7 day / 24 hr time clock function (Option BHB1) for
FX05 (Option
DG 1, 2, 5, 6)
206076
N2 Open Communication for J/C Interface (Opt BHB2) for
FX05
(Opt DG 1, 2, 5, 6)
206077
LONMARK Open Protocol Interface (Opt BHB3) for
FX05 used in Option DG 1, 2, 5, 6
Opt DG1
223415
Opt DG2
223416
Opt DG5
223417
Opt DG6
223418
N2 Open Communication for J/C Interface (Opt BHB2) for FX06
(D12B, D12C, D12F, D12G)
222054
LONMARK Open Protocol Interface (Opt BHB3)
Opt D12B
258237
Opt D12C
258238
Opt D12D
258239
Opt D12E
258240
Opt D12F
258241
35
Outside or Discharge Air Sensor, JC A99hj-200d, for
CODE 33
206112
36
Discharge Sensor Mixing Tube Holder (Used with both louvers and
ductwork; see page 30 for installation with louvers.)
115850
Code
Electrical Components in the Electric Heat Section - Models PEH and REH
Description
All Sizes
37A Controller Bracket
206139
37B
*Digital Controller FX06 with D12D Software
D12D
234685
*Digital Controller FX06 with D12E Software
D12E
234686
38
N2 Open Communication for J/C Interface (Opt BHB2) for FX06 used in
Option D12E and D12D
D12E
222054
D12D
222054
LONMARK Open Protocol Interface (Opt BHB3) for FX06 used in Option
D12E and D12D
D12E
258239
D12D
258240
CODE 31 - Venter Speed Controller used in Options AG 40, 60, 61, 62; DG 1, 2, 5, 6; D12B, D12C
Fuel
Natural Gas (AA1)
Propane (AA2)
Voltage
208/1,
208/3
(AK 2, 5)
230/1, 230/3,
460/3, 575/3
(AK 3, 6, 7 ,8)
208/1,
208/3
(AK 2, 5)
230/1, 230/3,
460/3, 575/3
(AK3,6,7,8)
75
215197
213583
215197
213583
100
215197
213584
215197
213584
125
213582
213579
213581
213579
150
213582
213577
213581
213579
175
213579
213577
213579
213578
200
213581
213578
213581
213578
225
213582
213579
213581
213577
250
213579
213576
213580
213576
300
213581
213579
213581
213579
350
213582
213581
213582
213581
400
213582
213581
213582
213581
P/N of
Control
(left)
% of
Full
Speed
Venter Speed Controller DIP Switch Settings
1
2
3
4
5
6
7
8
213576
56
ON ON ON OFF ON OFF ON ON
213577
58
ON OFF OFF ON ON OFF ON ON
213578
60
OFF ON OFF ON ON OFF ON ON
213579
62
OFF OFF ON ON ON OFF ON ON
213580
64
OFF ON ON ON ON OFF ON ON
213581
67
OFF OFF OFF OFF OFF ON ON ON
213582
70
ON ON OFF OFF OFF ON ON ON
213583
80
OFF OFF ON ON OFF ON ON ON
213584
85
ON OFF OFF OFF ON ON ON ON
215197
88
OFF OFF ON OFF ON ON ON ON
CODE 32A - Electronic
Filter, P/N 171738
(Options AG 40, 60, 61,
62; DG 1, 2, 5, 6)
CODE 32B - Time Delay
Relay, P/N 174810
(Options AG 40, 60, 61,
62; DG 1, 2, 5, 6)
*
Replacing FX06 controller
on units manufactured prior
to 12/2012 (Date Code BLL)
requires a new wiring harness;
order P/N 270294.