Digital controller fx05 for opt dg 6, Air sensor 6, Compartment 6, 7 – Reznor SDH Parts Manuals User Manual

Page 6: Electronic filter 6, Plug-in cards 6, Ube holder 6, Enter speed controller 6, Electrical components (cont’d)

Advertising
background image

Form P-PREEVA, P/N 263985R7, Page 6

CODE 33 - Programmable Digital Controllers

CODE 35 - Outdoor

and Discharge

Air Sensor for

CODE 33,

P/N 206112

CODE 34 -

Plug-in Cards

for CODE 33

CODE 36 - Discharge Air Mixing Tube and

Sensor Holder with Electrical Box and

Cover, P/N 115850 (used with AG 3, 15, 16,

40, 60, 61, 62; DG 5, 6; D12 B, C, F, G)

Bracket,

P/N

213612, (not

illustrated) is

required if used

on indoor unit with

optional louvers

(See page 30.).

Electrical Components (cont’d)

For location of factory installed components, see page 3.

Electric Heat Section

Electrical Compartment -

Models PEH and REH

(See locations, page 7.)

FX05 in Control

Options DG1,

DG2, DG5, and

DG6

FX06 in Control

Options D12B,

D12C, D12F, and

D12G

CODE Description

PDH/SDH/RDH All Sizes

(applicable

options)

SHH/RHH

PXH/RXH

Secondary Panel in the Gas Heat Section Electrical Compartment (low voltage)

showing Digital Heating/Cooling Controls (PDH/SDH/SHH/RHH/RDH) or Main

Electrical Compartment (not shown) on Models PXH/RXH - See illustrations, page 3.

33

Digital Controller

FX05 Packaged Assembly (includes

controller and software for specific Option DG1, DG2,

DG5, or DG6)

Opt DG1

213635

Opt DG2

213636

Opt DG5

213637

Opt DG6

213638

Digital Controller

FX06 for D12B, D12C, D12F, D12G

(includes controller and software for specific Option

D12B, D12C, D12F, or D12G)

Replacing FX06 controller on units manufactured

prior to 12/2012 (Date Code BLL) requires a new

wiring harness; order P/N 270294.

Opt D12B

223485

Opt D12C

223486

Opt D12F

257432

Opt D12G

260087

Digital Controller

FX07 w/D12B software (special not illustrated)

262460

34

Plug-in Cards for

CODE 33:

7 day / 24 hr time clock function (Option BHB1) for

FX05 (Option

DG 1, 2, 5, 6)

206076

N2 Open Communication for J/C Interface (Opt BHB2) for

FX05

(Opt DG 1, 2, 5, 6)

206077

LONMARK Open Protocol Interface (Opt BHB3) for

FX05 used in Option DG 1, 2, 5, 6

Opt DG1

223415

Opt DG2

223416

Opt DG5

223417

Opt DG6

223418

N2 Open Communication for J/C Interface (Opt BHB2) for FX06

(D12B, D12C, D12F, D12G)

222054

LONMARK Open Protocol Interface (Opt BHB3)

Opt D12B

258237

Opt D12C

258238

Opt D12D

258239

Opt D12E

258240

Opt D12F

258241

35

Outside or Discharge Air Sensor, JC A99hj-200d, for

CODE 33

206112

36

Discharge Sensor Mixing Tube Holder (Used with both louvers and

ductwork; see page 30 for installation with louvers.)

115850

Code

Electrical Components in the Electric Heat Section - Models PEH and REH

Description

All Sizes

37A Controller Bracket

206139

37B

*Digital Controller FX06 with D12D Software

D12D

234685

*Digital Controller FX06 with D12E Software

D12E

234686

38

N2 Open Communication for J/C Interface (Opt BHB2) for FX06 used in

Option D12E and D12D

D12E

222054

D12D

222054

LONMARK Open Protocol Interface (Opt BHB3) for FX06 used in Option

D12E and D12D

D12E

258239

D12D

258240

CODE 31 - Venter Speed Controller used in Options AG 40, 60, 61, 62; DG 1, 2, 5, 6; D12B, D12C

Fuel

Natural Gas (AA1)

Propane (AA2)

Voltage

208/1,

208/3

(AK 2, 5)

230/1, 230/3,

460/3, 575/3

(AK 3, 6, 7 ,8)

208/1,

208/3

(AK 2, 5)

230/1, 230/3,

460/3, 575/3

(AK3,6,7,8)

75

215197

213583

215197

213583

100

215197

213584

215197

213584

125

213582

213579

213581

213579

150

213582

213577

213581

213579

175

213579

213577

213579

213578

200

213581

213578

213581

213578

225

213582

213579

213581

213577

250

213579

213576

213580

213576

300

213581

213579

213581

213579

350

213582

213581

213582

213581

400

213582

213581

213582

213581

P/N of

Control

(left)

% of

Full

Speed

Venter Speed Controller DIP Switch Settings

1

2

3

4

5

6

7

8

213576

56

ON ON ON OFF ON OFF ON ON

213577

58

ON OFF OFF ON ON OFF ON ON

213578

60

OFF ON OFF ON ON OFF ON ON

213579

62

OFF OFF ON ON ON OFF ON ON

213580

64

OFF ON ON ON ON OFF ON ON

213581

67

OFF OFF OFF OFF OFF ON ON ON

213582

70

ON ON OFF OFF OFF ON ON ON

213583

80

OFF OFF ON ON OFF ON ON ON

213584

85

ON OFF OFF OFF ON ON ON ON

215197

88

OFF OFF ON OFF ON ON ON ON

CODE 32A - Electronic

Filter, P/N 171738

(Options AG 40, 60, 61,

62; DG 1, 2, 5, 6)

CODE 32B - Time Delay

Relay, P/N 174810

(Options AG 40, 60, 61,

62; DG 1, 2, 5, 6)

*

Replacing FX06 controller

on units manufactured prior

to 12/2012 (Date Code BLL)

requires a new wiring harness;

order P/N 270294.

Advertising