Qty
P/N
Description
12 16247 Cap Screw 5/16"-18 x 3/4" long
12
1035 Hex Nut 5/16" - 18
4
16243 Lag Screw 5/16" x 1" long
16
1333 Lockwasher 5/16"
1
66302 1/4" x 1-1/4" x 50' Foam Sealant Tape
Hardware and Tape
shipped with each
Roof Curb
Configuration
Curb Adapter (transition curb) for Model RDH Size
If ordering a Model
RDH. RXH or REH
with Modules (X)
To replace a similar Model RGB
or Model RPB with
75/100 125/150 125/150 175/200
/225
175/200
/225
250/300 350/400 350/400
To replace Model RGB or RPB Size
Mixing
Box
Cooling
Cabinet Downturn
Inlet Air
Discharge
Air
Roof
Curb
75/100
/125
125
150/175
175
200/225 250/300
350
400
Horizontal
(no damper) Horizontal CJ1
RSI 63-290- PA-01
PB-01
PB-02
PC-01
PC-02
PD-01
PE-01
PE-02
Reznor
®
P/N
216516 216520 216524 216528
216532 216536 216540 216544
H
inches
8
8
8
10
10
10
8
8
mm
203
203
203
254
254
254
203
203
X
Horizontal with
Damper; Bottom;
or
Hrzntal & Btm
Horizontal CJ1 RSI 63-290-
Special Order - Contact your Reznor
®
distributor.
X
Horizontal
(no damper)
Bottom
CJ2
RSI 63-290- PA-02
PB-03
PB-04
PC-03
PC-04
PD-02
PE-03
PE-04
Reznor
®
P/N
216517 216521 216525 216529
216533 216537 216541 216545
H
inches
8
8
8
10
10
13
10
10
mm
203
203
203
254
254
330
254
254
X
X
Horizontal with
Damper; Bottom;
or Horizontal and
Bottom
Bottom
CJ2
RSI 63-290- PA-05
PB-09
PB-10
PC-09
PC-10
PD-05
PE-09
PE-10
Reznor
®
P/N
220906 220907 220908 220909
220910 220911 220912 220913
H
inches
13
13
13
15
15
15
16
16
mm
330
330
330
381
381
381
406
406
X
Horizontal (no
damper)
Horizontal CJ4 RSI 63-290-
Special Order - Contact your Reznor
®
distributor.
X
X
Horizontal with
Damper; Bottom;
or Horizontal and
Bottom
Horizontal CJ4
RSI 63-290- PA-03
PB-05
PB-06
PC-05
PC-06
PD-03
PE-05
PE-06
Reznor
®
P/N
216518 216522 216526 216530
216534 216538 216542 216546
H
inches
10
10
10
13
13
13
10
10
mm
254
254
254
330
330
330
254
254
X
X
Horizontal (no
damper)
Bottom
CJ5 RSI 63-290-
Special Order - Contact your distributor.
X
X
X
Horizontal with
Damper; Bottom;
or Horizontal and
Bottom
Bottom
CJ5
RSI 63-290- PA-04
PB-07
PB-08
PC-07
PC-08
PD-04
PE-07
PE-08
Reznor
®
P/N
216519 216523 216527 216531
216535 216539 216543 216547
H
inches
10
10
10
13
13
13
10
10
mm
254
254
254
330
330
330
254
254
Opening
matches
return
duct.
Opening
matches
supply
duct.
Transition Curb
for RDH
Supply
Duct
Return
Duct
Original Curb (CJ 1, 2, 4, or 5)
H
CODE 311 - Curb Adapter (Transition Curb) for use when Installing a Model RDH on an existing CJ
Roof Curb
Transition Curb Features: Heavy-gauge G-90 galvanized steel; Fully seam welded (air and water tight); Welds
coated with rust inhibitor; Internally insulated with 2” insulation; Gasketing provided for field installation
CODE 310A - Roof Curb
Hardware - Included in
CODES 310, 312, and
313
Model RXH with HW2 Configuration
Option RXH with Option HW2 Pkg P/N
Curb End (Front & Rear) Assy Curb Side Assy
Model RXH with Optional Hot Water Heat Module (HW2)
and horizontal discharge
CJ8H
000A
260877
(2) 261546
(2) 261522
000B
260878
(2) 261547
(2) 261522
000C
260879
(2) 261546
(2) 261523
000D
260880
(2) 261548
(2) 261523
000E
260881
(2) 261549
(2) 261523
Model RXH with Optional Hot Water Heat Module (HW2)
PLUS 1 either Downturn Discharge Plenum (AQ5 or
AQ8); OR Mixing Box (MXB1) with horizontal discharge;
OR Cooling Coil Cabinet without Reheat (AU5 or AU6)
with horizontal discharge
CJ8J
000A
260882
(2) 261546
(2) 261524
000B
260883
(2) 261547
(2) 261524
000C
260884
(2) 261546
(2) 261525
000D
260885
(2) 261548
(2) 261525
000E
260886
(2) 261549
(2) 261525
Model RXH with Optional Hot Water Heat Module (HW2)
PLUS 2 - Down Discharge (AQ 5 or AQ8) AND Mixing Box
OR Cooling Coil Cabinet without Reheat (AU 5 or 6); OR
Mixing Box AND Cooling Coil Cabinet without Reheat
(AU 5 or 6) with horizontal discharge
CJ8K
000A
260887
(2) 261546
(2) 261526
000B
260888
(2) 261547
(2) 261526
000C
260889
(2) 261546
(2) 261527
000D
260890
(2) 261548
(2) 261527
000E
260891
(2) 261549
(2) 261527
Model RXH with Optional Hot Water Heat Module (HW2)
PLUS 3 - Down Discharge Plenum (AQ5 or AQ8) AND
Mixing Box (MXB1) AND Cooling Coil Cabinet without
Reheat (AU5 or AU6)
CJ8L
000A
260892
(2) 261546
(2) 261528
000B
260893
(2) 261547
(2) 261528
000C
260894
(2) 261546
(2) 261529
000D
260895
(2) 261548
(2) 261529
000E
260896
(2) 261549
(2) 261529
Model RXH with Optional Hot Water Heat Module (HW2)
PLUS 1 -
Cooling Coil Cabinet with Reheat (AU7) with horizontal
discharge
CJ8M
000A
260897
(2) 261546
(2) 261530
000B
260898
(2) 261547
(2) 261530
000C
260899
(2) 261546
(2) 261531
000D
260900
(2) 261548
(2) 261531
000E
260901
(2) 261549
(2) 261531
Model RXH with Optional Hot Water Heat Module (HW2)
PLUS 2 -
Cooling Coil Cabinet with Reheat (AU7) AND Down
Discharge Plenum (AQ5 or AQ8) OR Mixing Box (MXB1)
with horizontal discharge
CJ8N
000A
260902
(2) 261546
(2) 261532
000B
260903
(2) 261547
(2) 261532
000C
260904
(2) 261546
(2) 261458
000D
260905
(2) 261548
(2) 261458
000E
260906
(2) 261549
(2) 261458
Model RXH with Optional Hot Water Heat Module (HW2)
PLUS 3 -
Cooling Coil Cabinet with Reheat (AU7) AND Down
Discharge Plenum (AQ5 or AQ8) AND Mixing Box (MXB1)
CJ8P
000A
260907
(2) 261546
(2) 261459
000B
260908
(2) 261547
(2) 261459
000C
260909
(2) 261546
(2) 261545
000D
260910
(2) 261548
(2) 261545
000E
260911
(2) 261549
(2) 261545
CODE 312 - Roof Curbs - Model RXH with Option HW2 (hot water heat coil)