Capacitor 15, 26, Ap 15, Enter components 15, 16 – Reznor SDH Parts Manuals User Manual
Page 15: Enter housing 15, 16, Enter motor 15, 16, Enter motor capacitor 15, Wheel 15, 16, Venter components, Models pdh, sdh & rdh

Form P-PREEVA, P/N 263985R7, Page 15
CODE 113 - Two-Speed
Blower Motors
HP
Reznor
®
P/N
Magnetec
No.
Volt PH Frame Shaft
Diameter
Overload
ABB Motor
Starter Pkg
Reznor
®
P/N
High Speed Low Speed
1-.44
105641
M124
208 3 M145T
7/8
3.8
2.4
A16ST-80H2K
114971
1-.44
105641
M124
240 3 M145T
7/8
3.4
2.2
A16ST-80H2K
114971
1-.44
105642
M109
480 3 M145T
7/8
1.7
1.1
A16ST-51F2G
114972
1.5-.68
105643
M125
208 3 N145T
7/8
5.4
3.1
A16ST-80J2M
114973
1.5-.68
105643
M125
240 3 N145T
7/8
4.9
2.8
A16ST-80J2M
114973
1.5-.68
105644
M104
480 3 N145T
7/8
2.4
1.4
A16ST-51G2J
114974
2-.88
105645
M220
208 3 S182T
1 1/8
6.5
4.2
114975
2-.88
105645
M220
240 3 S182T
1 1/8
5.9
3.8
A16ST-80K2M
114976
2-.88
105646
M207
480 3 S182T
1 1/8
3.4
2.1
A16ST-51H2K
114977
3-1.3
105647
M221
208 3 S184T
1 1/8
9.3
5.3
A16ST-80M2P
114978
3-1.3
105647
M221
240 3 S184T
1 1/8
8.4
4.8
A16ST-80M2P
114978
3-1.3
105648
M208
480 3 S184T
1 1/8
4.6
2.6
A16ST-51J2L
114979
N.O. Auxiliary Contacts, Option AO3, AEG Model HS17.10, 10A, 600 V,
P/N 115951
N.C. Auxiliary Contacts, Option AO4, AEG Model HS17.01, 10A, 600 V,
P/N 115952
CODE 110 - Blower Motor (cont’d)
Starter (AN10) Reznor
®
P/N
Starter Overload Reznor
®
P/N
Type HP Option AL
P/N
Mfr's No.
Frame Fla Shaft Volt ph
Mfr's No.
Min Max GE #
EE
2
36, 37, 38
159027
E1017
145T 2.9 7/8" 480 3
CL00A310T-1
151275 2.5 4.1 RTA1-K 151190
EE
2
36, 37, 38
158176
AOS H965V1
P145T 2.1 7/8" 575 3
CL00A310T-1
151275 1.9 2.7 RTA1-J 151189
EE
3
39
159186 B-35L405S489G3 145T 8.3 7/8" 208 3
CL00A310T-1
151275
8
12 RTA1-N
151193
EE
3
39
159028
B-EM3158T
145T 7.4 7/8" 240 3
CL00A310T-1
151275 5.5 8.5 RTA1-N 151192
EE
3
39
159028
B-EM3158T
145T 3.7 7/8" 480 3
CL00A310T-1
151275 2.5 4.1 RTA1-K 151190
EE
3
39
159030 B-35L405S709G1 145T 3
7/8" 575 3
CL00A310T-1
151275 2.5 4.1 RTA1-K 151190
EE
5
27
159029
E204
H182T 13.9 1-1/8" 208 3
CL02A310T-1
151277
10
16 RTA1-P
151194
EE
5
27
159029
E204
H182T 11.6 1-1/8" 240 3
CL01A310T-1
151276
10
16 RTA1-P
151194
EE
5
27
159029
E204
H182T 5.8 1-1/8" 480 3
CL00A310T-1
151275 5.5 8.5 RTA1-M 151192
EE
5
27
111602
BAL-M3613T-5
184T 4.8 1-1/8" 575 3
CL00A310T-1
151275
4
6.3 RTA1-L
151191
Venter Components
Models PDH, SDH & RDH
5/16 (8mm) inside - Sizes 75-150
7/16 (11mm) inside - 175-400A
Venter
Motor
Venter
Wheel
117J
117C
117F
117K,L
117A
117H
CODE 117 - Venter Motor and
Wheel Assembly
CODE 118 - Venter
Motor Capacitor
114
115
116
Venter Housing and Gasket
PDH / SDH / RDH
CODE
Description
75 100 125
150 175 200 225 250 300 350
400A
114 Venter Housing Gasket
196012
196013
115
Venter
Housing
(
with hole
for pressure
sensor.)
Manufactured after
Sept. 22, 2010
196248
259680
Manufactured prior
to Sept. 22, 2010
196248
210929
116 Static Pressure Tap
116043
117
Venter
Motor and
Wheel
Assembly
(includes
117A-L)
115V/1ph
214592
214593
214594
214595
208/230V/1ph
214596
214597
214598
214599
208/230V/3ph
460V
575V
117A Venter
Motor
115V/1ph 260422*
196036
196037
196236
*Sizes 75&100 mfgd prior to 10/10, order Kit P/N 262444
208/230V/1ph
196827
196828
196829
196830
208/230V/3ph
460V
575V
117B Wheel
135979, 5-1/16"dia x 2"W
195666, 6-5/16"dia x 2"W
117C Spacer (isolator bushing)
(3)
194803, #10x.310
117D Venter Motor Clip
(3)
194805
117E Venter Motor Mounting Plate
194806
194910
117F Venter Motor Plate Gasket
--
--
--
--
254935
117G Cooling Fan
195766
196035
117H Motor Mounting Bracket
195072
117J Isolator
(3)
194534
117K Isolator Screw
(3)
202949
118
Venter
Motor
Capacitor
115V/1ph --
--
195641,
4 mfd
195643, 7.5 mfd
195642, 5 mfd
208/230V/1ph --
--
195642, 5 mfd
195641, 4 mfd
208/230V/3ph --
--
460V --
--
575V --
--
119 Transformer for 460 & 575V
210862, 200VA
210863, 350VA