Flexible gas connection 23, Alve 23, 25, 26, 27, Components 23, 25, 26 – Reznor P125 YDSA Parts Manuals User Manual
Page 23: Option ag72

Form P-Y (01-15), PN 273651R6, Page 23
69
Flame Sensor
(Not Shown)
Option AG72
4 Stage 25/50/75/100 Control
Dual Heat Sections Manifold Assembly
Heat Section 2
65
Heat Section 1
67
66
68
72
73
74
75
70
79
77
Limit Control
(Not Shown)
71
76
Flame Sensor
(Not Shown)
78
80
Option AG72 - Dual Heat Section Manifold Code Number Details:
WITH:
AA1 - Natural Gas Option with BP1 Standard Manifold.
AA1 - Natural Gas Option with BP4 Manifold with High & Low Pressure Switches.
AA2 - Propane Option with BP1 Standard Manifold.
AA2 - Propane Option with BP4 Manifold with High & Low Pressure Switches.
Code
Description
Standard Efficiency
High Efficiency
H102 H125 H150 H175 H202 H402 H502 H602 H702 H802
G302
G372 G452 G525 G602
65 & 72 Heat Exchanger Assy
See Single & Dual Heat Section Mod Ass’y Tables on Page 21
66 & 73 Spark Ignitor
272742
67
Limit Control
---
272740
272741
272740
272741
272740
74
Limit Control
---
272740
272741
272740
272741
272740
68
Gas Valve:
AA1 - Natual Gas Option
177396
177397
177396
177397
AA2 - Propane Option
---
177395
177398
---
69 & 76 Flame Sensor
(typical all AA_ options)
272743
70 & 78 BP4 Optional High Gas
Pressure Switch
204297
71 & 79 Venter Assembly
See Standard Efficiency Gas Venter Assembly Usage Table on Page 45
75
Gas Valve:
AA1 - Natual Gas Option
177396
177397
177396
177397
AA2 - Propane Option
---
177395
177398
---
77
BP4 Optional Low Gas
Pressure Switch
204375
80
Flexible Gas Connection
273794
120875
273794
120875
H102 H125 H150 H175 H202 H402 H502 H602 H702 H802
G302
G372 G452 G525 G602
NOTE: Heat sections illustrated are standard efficiency, non-condensing furnaces. Controls for condensing furnaces are the same