Date of manufacture 3, Rating plate 3, Able 3 – Reznor P125 YDSA Parts Manuals User Manual
Page 3: Serial no. date of manufacture table

Form P-Y (01-15), PN 273651R6, Page 3
MERCER, PA USA 16137
MADE IN U.S.A.
DUCT FURNACE/GÉNÉRATEUR D’AIR CHAUD À GAINE
CATEGORY III/CATÉGORIE III
FOR INDUSTRIAL/COMMERCIAL USE ONLY
POUR USAGE INDUSTRIEL/COMMERCIAL
ANSI Z83.8
[AA] - [ A ]
CSA 2.6
[AA1] - [A1] DUCT FURNACE/GÉNÉRATEUR D’AIR CHAUD À GAINE
MODEL/MODÈLE [ C ] [ P ]
SERIAL NO. / #DE SÉRIE: [ ]
230 VOLTS 1 PH 60 HZ MAXIMUM TOTAL INPUT
[ D ] AMPS
CONSOMMATION TOTALE MAX DE
[ D ] AMPS
TYPE OF GAS/TYPE DE GAZ: [ E ]
ALTITUDE
[ Q ] FEET/PIEDS, [ R ] MÈTRES
BURNER ORIFICE SIZE [
F ] DRILL HAS BEEN FACTORY ADJUSTED
BRULEUR DIMENSION DE L’ORIFICE [
F ] FORET
NORMAL INPUT/ENTRÉE NORMALE (TOTAL)
[
H ] BTU/HR
THERMAL OUTPUT / RENDEMENT THERMIQUE (TOTAL)
[
I ] BTU/HR
MINIMUM INPUT/ENTRÉE MIN.
[
J ] BTU/HR
NORMAL MANIFOLD PRESSURE
[
K ] IN.W.C.
PRESSION NORMALE DE LA TUB
[
K ] PO/COL D’EAU
MIN. PERMISSIBLE GAS SUPPLY PRESSURE
FOR PURPOSE OF INPUT ADJUSTMENT. [
L ] IN.W.C.
PRES. D’ALIM. MIN. ACCEPTABLE DE GAZ POUR
DES FIN DE RÉGLAGE DE L’ENTRÉE
[
L ] PO/COL D’EAU
MAXIMUM THROUGHPUT / MINIMUM THROUGHPUT [
M ] / [ N ] C.F.M.
CONSOMMATION MAXIMUM / MINIMUM [
M ] / [ N ] PI3/MN
Gas Heat Section Rating Plate Key:
AA, A = ANSI Standard and Date
AA1, A1 = CSA Standard and Date
C = Model No.
D = Voltage
E = Type of Gas (natural)
F = Orifice Size
H = Normal BTU/Hour Input (sea level)
I = Thermal Output BTU/Hour (sea level)
J = Minimum BTU/Hour Input (sea level)
K = Manifold Pressure
L = Minimum Gas Supply Pressure
M = Maximum Throughput
N = Minimum Throughput
P = Manufacturing Date (Month/Year)
Q = Altitude in Feet
R = Altitude in Meters
Serial No. Date of Manufacture Table
Year
Jan
Feb
Mar
Apr
May
June
July
Aug
Sept
Oct
Nov
Dec
2013
BMA
BMB
BMC
BMD
BME
BMF
BMG
BMH
BMI
BMJ
BMK
BML
2014
BNA
BNB
BNC
BND
BNE
BNF
BNG
BNH
BNI
BNJ
BNK
BNL
2015
BOA
BOB
BOC
BOD
BOE
BOF
BOG
BOH
BOI
BOJ
BOK
BOL
2016
BPA
BPB
BPC
BPD
BPE
BPF
BPG
BPH
BPI
BPJ
BPK
BPL
2017
BQA
BQB
BQC
BQD
BQE
BQF
BQG
BQH
BQI
BQJ
BQK
BQL
2018
BRA
BRB
BRC
BRD
BRE
BRF
BRG
BRH
BRI
BRJ
BRK
BRL
2019
BSA
BSB
BSC
BSD
BSE
BSF
BSG
BSH
BSI
BSJ
BSK
BSL
2020
BTA
BTB
BTC
BTD
BTE
BTF
BTG
BTH
BTI
BTJ
BTK
BTL
2021
BUA
BUB
BUC
BUD
BUE
BUF
BUG
BUH
BUI
BUJ
BUK
BUL
2022
BVA
BVB
BVC
BVD
BVE
BVF
BVG
BVH
BVI
BVJ
BVK
BVL
2023
BWA
BWB
BWC
BWD
BWE
BWF
BWG
BWH
BWI
BWJ
BWK
BWL
2024
BXA
BXB
BXC
BXD
BXE
BXF
BXG
BXH
BXI
BXJ
BXK
BXL
2025
BYA
BYB
BYC
BYD
BYE
BYF
BYG
BYH
BYI
BYJ
BYK
BYL
Sample of a Optional Gas Heat Section Rating Plate
RAD