Electric heat components (cont’d), Ydha, ydma & ydsa electrical components (cont’d), Compression – Reznor P125 YDSA Parts Manuals User Manual

Page 40: See component illustrations page 33

Advertising
background image

Form P-Y (01-15), PN 273651R6, Page 40

YDHA, YDMA & YDSA Electrical

Components (Cont’d)

AK5

AK6

AK7

AK8

Model

Size

208 / 3 / 60 230 / 3 / 60 460 / 3 / 60 575 / 3 / 60

Opt

Description

Qty

P/N

P/N

P/N

P/N

(NOTE: E90 continued from previous page)

E90

Stage 3 Fuseblock A

1

207618

207630

YDSA

180, 210

Stage 3 Fuseblock B

1

207631

---

Stage 1 Fuse A

3

207615

207627

Stage 1 Fuse B

3

207617

---

Stage 2 Fuse A

3

207615

207627

Stage 2 Fuse B

3

207617

---

Stage 3 Fuse A

3

207615

207627

Stage 3 Fuse B

3

207617

---

E120

Heater Rack

12

272505

272506

272507

YDHA, YDMA

180, 210, 240, 300, 360

SCR Module

1

234057

220688

234058

SCR Contactor

1

272416

272416

Step 2 Contactor

1

Step 3 Contactor

1

Step 4 Contactor

1

---

Step 5 Contactor

1

Step 6 Contactor

1

SCR Fuseblock

1

207631

207630

Step 2 Fuseblock

1

Step 3 Fuseblock

1

Step 4 Fuseblock

1

Step 5 Fuseblock

1

---

Step 6 Fuseblock

1

SCR Fuse

3

207617

207628

Step 2 Fuse

3

Step 3 Fuse

3

Step 4 Fuse

3

Step 5 Fuse

3

---

---

Step 6 Fuse

3

---

---

Heater Rack

12

272505

272506

272507

YDSA

180, 210

Stage 1 Contactor A

1

272001

272416

Stage 1 Contactor B

1

272416

---

Stage 2 Contactor A

1

272001

272416

Stage 2 Contactor B

1

272416

---

Stage 3 Contactor A

1

272001

272416

Stage 3 Contactor B

1

272416

---

Stage 4 Contactor A

1

272001

272416

Stage 4 Contactor B

1

272416

---

Stage 1 Fuseblock A

1

207618

207630

Stage 1 Fuseblock B

1

207631

---

Stage 2 Fuseblock A

1

207618

207630

Stage 2 Fuseblock B

1

207631

---

Stage 3 Fuseblock A

1

207618

207630

Stage 3 Fuseblock B

1

207631

---

Stage 4 Fuseblock A

1

207618

207630

Stage 4 Fuseblock B

1

207631

---

Stage 1 Fuse A

3

207615

207627

Stage 1 Fuse B

3

207617

---

Stage 2 Fuse A

3

207615

207627

Stage 2 Fuse B

3

207617

---

Stage 3 Fuse A

3

207615

207627

Stage 3 Fuse B

3

207617

---

Stage 4 Fuse A

3

207615

207627

Stage 4 Fuse B

3

207617

---

YDHA & YDMA, Dehumidication

Components with Option RPLE

(Low Capacity Reheat Pump)

Unit Supply Voltage Options AK_

AK3

AK5

AK6

AK7

AK8

AK12

230 / 1 / 60 208 / 3 / 60 230 / 3 / 60 460 / 3 / 60 575 / 3 / 60 400 / 3 / 50

Compression

Code Description

Qty

P/N

P/N

P/N

P/N

P/N

P/N

Model

Size

150 Compressors

1

272641

259288

259355

272635

259355

YDHA, YDMA

60

1

272641

259288

259355

272635

---

YDMA

90

1

---

259288

259355

272635

259355

YDHA, YDMA

120

1

---

259288

259355

272635

259355

YDHA, YDMA

150

1

---

259288

259355

272635

259355

YDHA, YDMA

180, 210, 240

1

---

262801

262802

262803

262802

YDHA, YDMA

300, 360

151 Digital Controller

1

266067

YDHA, YDMA

All

152 Thermister

1

266069

YDHA, YDMA

60

1

266069

---

YDMA

90

1

---

266069

YDHA, YDMA

120, 150, 180,

210, 240, 300,

360

Cooling and Dehumidifying Components - Refrigerant is R-410A.

See component illustrations page 33

Electric Heat Components (Cont’d)

Advertising