General safety instructions

The manufacturer will not be held liable for claims for damage resulting from the following:
• Faulty assembly or connection
• Damage to the unit from mechanical influences, misuse or abuse
• Alterations to the unit without express written permission from the manufacturer
• Use for purposes other than those described in the operating manual

Dometic Tank Monitor

General safety instructions

3

Intended use

(fig . , page 2)

DTM01C Tank Monitor panel indicates when a wastewater holding tank is almost full . This monitor helps
prevent damage to the boat that can happen because of accidental overfilling of the holding tank .

Caution!
Operator must know local regulations for emptying a holding tank .

4

Components and Functions

Probe Cap with Float Switch
The probe cap installs into a threaded 3-inch (76 mm) FPT opening on the top of a Dometic

®

holding

tank or other holding tank equipped with such an opening . As the level of holding tank contents
rises, the float switch inside the tank is pushed upward and activates the “Full Tank” light on the
indicator panel .

Indicator Panel
The indicator panel has a single light which is activated by the float switch inside the holding tank .
When the “Full Tank” light is activated, the operation of any plumbing fixture connected to the
holding tank should stop until the tank is emptied .

1

Items in fig. , page 2

Description

1

Probe cap with float switch

2

Indicator panel

3

#6 fasteners

2

5

Specifications

5.1

Materials

Average current consumption: 0 .016 amps at 12 V DC . Requires 0 .5-amp fuse .

5.2

Electrical Current Draw

ISO8846; EMC Directive 2004/108/EC

5.3

Approvals

Panel frame:

ABS

Panel:

Polyester

Probe cap:

PVC

Float switch:

Nitrile rubber ebonite