SeaLand DTM01C Tank Monitor User Manual

Page 5

Advertising
background image

5

1 . Route 18-gauge stranded copper wire from DC Ground source to probe cap .

2 . Using quick-disconnect terminals, make proper wiring connections from DC Ground source and

indicator panel to probe cap wires . Refer to wiring diagram (fig . , page 4) .

3 . With probe cap removed from tank, turn on electrical power to system . Move black float up and

down to assure proper operation of float and indicator light . Red indicator light should
illuminate when float is pushed up . After successful test, turn off electrical power and
disconnect wires at quick-connect terminals .

4 . Install probe cap into 76 mm (3 in .) diameter port in top of holding tank . Tighten 1/4 turn beyond

hand tight . Re-connect wires and turn on electrical power .

6.2

Probe Cap

(fig . , page 2)

4

Dometic Tank Monitor

Installation

Caution!
Do not use probe cap in fuel tank.
Never install the probe cap with float switch into a
tank that contains anything other than wastewater, gray water or fresh water .

Note
For installation in sailboats: Locate probe cap on athwartships centerline of tank to
assure accuracy when heeled .

6

5