Service mode, Flush switch wall templates – SeaLand DFP flush switches User Manual

Page 7

Advertising
background image

7

“DO NOT FLUSH” INDICATOR

A red “Do Not Flush” light indicate two possible toilet system conditions:
1. vacuum level in toilet system is not sufficient for complete flush.
2. holding tank is full and should be pumped out. When the red light is on,
electrical power to the toilet automatically shuts off to prevent possible overfilling of
the holding tank.

4.5

Service mode

To clean the toilet bowl or perform other service that requires keeping the flush ball
open without running water, use the Service switch.
1.

Push the Service button for three seconds. The steady backlight will change to

a flashing light while the toilet is in Service mode.
2.

Perform the service operation. After the Service operation is complete, press

the Service buttom for three seconds to change back to normal toilet operation.

2 in. (51 mm) clearance

behind wall surface required

2.5 in. (64 mm)

2.25 in.

(57 mm)

2 in. (51 mm) clearance

behind wall surface required

1.875 in. (64 mm)

2 in.

(51 mm)

VFP and DFP

WALL BRACKET

VFP and DFP

WALL BRACKET

VFS and DFS

WALL BRACKET

5

Flush Switch

Wall Templates

Note
See important information
on back page before using
either template.

Advertising
This manual is related to the following products: