TRoubLeShooTING (cont’d)

SyMPToM 3. flush valve will not close.

Condition/Procedure
Mode Switch is in SERVICE

position:
Foreign object prevents the flush

valve from closing and the safety

circuit locked flush valve in open

position:
Check the voltage output to

the flush valve motor at

pins 9 and 0 on the control

module as follows:

Corrective Action
• Return switch to the “Normal” position.

• Reset the control circuit by putting the Mode Switch in the SERVICE

position temporarily, then returning to the NORMAL position. If the

flush valve

did not close, go to next step.

• Pull the control module out as far as the control cables will allow.
• Disconnect either the orange or green wire from the Closed Limit

Switch.

• With DC voltmeter test leads across pins 9 and 10, flip the Mode

Switch between the SERVICE and NORMAL positions. If voltage is

present for about two seconds in the NORMAL position, the flush

valve motor or related wiring is defective.

• If voltage is not present, replace the control module.

SYMPTOM 4. Water will not enter toilet bowl during a flush and when the flush handle is raised

or the flush switch is pushed to “Add Water”.

Procedure
Check the “WATER VALVE”

status light while pushing the

"Flush" switch on the control

panel:

Corrective Action
• If the “WATER VALVE” status light comes on, the water valve filter

screen may be plugged with debris, or the water valve or its related

wiring is defective.

• If the “WATER VALVE” status light remains off, replace the control

module.

• If voltage is not present, replace the control module.

SYMPTOM 5. Flush valve will not open when Mode Switch is in the “Service” position but opens

during a normal flush cycle.

Corrective Action
• Replace control module.