ToILeT INSTALLATIoN INSTRucTIoNS

System Requirements:
• 2 GPM (0.6 lpm) or larger water pump.
• 1/2-inch (12.7 mm) water line terminating in 1/2-inch MPT fitting (to connect to toilet water supply hose).
• 4-bolt floor (closet) flange. SeaLand flanges available include 3-inch spigot, socket, MPT, or 45-degree swivel

socket.

• 2 VDC through 7- or 8-amp fuse or circuit breaker. Use 4-gauge stranded copper wire.

IMPoRTANT: If replacing an existing gravity-discharge toilet, make sure the center of the existing discharge

flange is at least 11-1/4 inches from the back wall, then proceed to Step 5 for proper positioning of water

line and electrical wiring.
STEP 1: Carefully unpack the toilet bowl, rear access lid and floor flange adapter.

cAuTIoN: hANdLe The vIT-

ReouS chINA ToILeT ANd AcceSS LId WITh cARe. SeT The LId IN AN AReA WheRe IT cANNoT be

bRoKeN. PLAce LId oN ToILeT oNLy AfTeR ToILeT INSTALLATIoN IS coMPLeTe.
STEP 2: Position the ceramic bowl in the space intended. Confirm that adequate clearance is available for using the

flush handle and opening the seat and lid.
STEP 3: Mark the floor at the rear corners of the toilet bowl (fig. 1). Measure the distance between the two marks

and divide by 2 to find the toilet centerline. Mark the floor at the rear wall for the centerline.
STEP 4: Place a carpenter’s square against the back wall, and draw a center line on the floor at least 14 inches

(356 mm) long (fig. 2). Mark the centerline for the floor flange at 11-1/4 inches (286 mm) from the wall (fig. 3).

fig. 2

Fig. 1

fig. 3

ToILeT dIMeNSIoNS

Dimensions may vary

±3/8-inch (13mm).