TRoubLeShooTING (cont’d)

SyMPToM 6. Water will not stay in bowl.

Condition/Procedure
Put Mode Switch in “Service”

position:
Worn or damaged flush valve ball

and seal:

Corrective Action
• Clean underside of flush valve ball seal of dirt and debris.

• Remove toilet from floor and remove base assembly from toilet and

replace flush valve ball and seals.

SYMPTOM 7. Water will not shut off and overflows the toilet.

Procedure
Check the “WATER VALVE” status

light:

Corrective Action
• If the light is

on when not flushing the toilet or adding water, replace

the control module. If the light responds correctly, go to next step.

• Dirt or debris lodged in the water valve seal. Remove the toilet from

the floor, disassamble and clean water valve.

• Replace water valve.

SYMPTOM 8. Water is leaking from under the toilet.

Procedure
Remove the toilet from the

floor and inspect the following

with both water and electrical

power applied:

(Place a container under the base

assembly to catch any water during

the inspection procedure.)

• Water hoses and fittings, water valve assembly
• Ceramic toilet bowl
• Upper base seal
• Flush valve ball rotor shaft shaft
• Base assembly