WARNING: When using this device, always exercise basic safety precautions, including the

following:
•

Read all instructions before installation or use.

•

Never connect this device to any electrical circuit with other than 2 or 24 volt Direct Current

or exceed the amperage draw listed.

•

Never install the indicator panel in an atmosphere with potentially flammable or explosive vapors.

•

This product is not to be installed in shower facilities.

•

Control panel can be wired directly to the TankWatch

®

4 panel.

•

Includes keyed selector switch and “discharge pump on” light. An optional “check seacock”

light is available to use in conjunction with a seacock interlock switch.

•

Prevents accidental overboard discharge in restricted waters when control switch is turned

to “off” position.

•

Two different modes, automatic or manual, for holding tank discharge pump control.

•

Discharges sewage directly overboard in unrestricted waters while in the “automatic” mode.

•

The “manual” mode provides direct discharge pump control regardless of the level of the

holding tank.

•

The “automatic” mode will automatically maintain holding tank at empty level and eliminate

stagnating sewage trapped in interconnecting hoses by wye valve operation.

•

In the “automatic” mode, the full-level float will turn on the discharge pump if the mid-level float

fails.

•

Simplifies plumbing by eliminating wye valves, seacocks, and vented loops for multiple toilet

installations.

•

For use with a T-series discharge pump, TankWatch

®

4 level monitor system, and optional

seacock interlock system.

•

2 and 24 VDC models available.

The TankMaster Automatic Discharge Pump Controller is designed to provide two different modes

to empty a wastewater or graywater holding tank: either automatic or manual. In the automatic

mode, the high-level switch (mid-float of a TankWatch

®

4 system) will activate the discharge pump.

The pump will then run until the low-level switch (low float of a TankWatch

®

4 system) is

deactivated. The manual mode turns on the discharge pump regardless of the liquid level in the

holding tank. Some fine-tuning of the float switch locations may be necessary in order to obtain

proper operation of the TankMaster controller.
NOTE: Keep in mind that once you enter a “no discharge zone,” your TankMaster must be

switched to the “off” position and the key removed to prevent illegally discharging your holding tank.

The United States Coast Guard will allow a key-operated switch as a means to secure the over-

board discharge pump system instead of securing it with a padlock or wire tie.

SAfETy fEATURES

PRODUCT fEATURES

Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Product Features . . . . . . . . . . . . . . . . . . . . . . . . . 2

System Operation Diagram . . . . . . . . . . . . . . . . . 3

Models and Accessories. . . . . . . . . . . . . . . . . . . . 4

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Installation Instructions . . . . . . . . . . . . . . . . . . . . 5

Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . 6

Dimensional Specifications. . . . . . . . . . . . . . . . . . 7

Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Troubleshooting Guide . . . . . . . . . . . . . . . . . 8 - 0

Control Panel Mounting Template . . . . . . . . . . . 

Manufacturer’s One-Year Limited Warranty . . . 2

Advertising