MODELS AND ACCESSORIES

Part Number

Description

338402

TM4-2 (2VDC) TankMaster

4

3384024

TM4-24 (24VDC) TankMaster

4

3380402

TM4-2SCL (2VDC) TankMaster

4 with Seacock Monitoring Light

33804024

TM4-24SCL (24VDC) TankMaster

4 with Seacock Monitoring Light

3730200

T-2 (2 VDC) Discharge Pump

37302400

T-24 (24 VDC) Discharge Pump

600343497

Seacock Interlock Switch for Conbraco -/2" Seacock Only

600343675

Seacock Interlock Switch for Groco -/2" Seacock Only

336003

TankWatch

®

4 Panel and Cap with Vent, 22-inch Probes

336004

TankWatch

®

4 Panel and Cap without Vent, 22-inch Probes

336005

TankWatch

®

4 Panel and Cap with Vent, 45-inch Probes

336006

TankWatch

®

4 Panel and Cap without Vent, 45-inch Probes

385230272

Universal Flange (3-inch NPT) with gasket and stainless steel hardware

60034292

Plug In Relay, 2VDC

600342490

Plug In Relay, 24VDC

3853874

“Do Not Flush” Panel

33000355

Level Indicator Cap without Vent, 22-inch Probes

33000350

Level Indicator Cap with Vent, 22-inch Probes

33000346

Level Indicator Cap without Vent, 45-inch Probes

33000345

Level Indicator Cap with Vent, 45-inch Probes

SPECIfICATIONS

Product Name:

TankMaster

4 Automatic Discharge Pump Controller

Electrical:

2-pin terminal block allows up to one 2-gauge wire per position.

Output Current Capability

Maximum relay rating for 2 or 24 VDC Discharge Pump: 40 amps inrush,

30 amps continuous.

Float Switch Rating: 20 watts with resistive load.

Current Consumption

“Standby” Current Draw:

2 volts DC: 0.060 amps

24 volts DC: 0.030 amps

“Pump On” Current Draw (not including pump):

2 volts DC: 0.60 amps

24 volts DC: 0.080 amps

Materials:

Control Panel Housing — Polypropylene

Face Plate — Polystyrene with protective coating

Keylock Switch — Stainless steel facing

Key — Nickel-plated brass

Advertising