8 troubleshooting guide – SeaLand 4800 Series VacuFlush User Manual

Page 11

Advertising
background image

11

SeaLand 4800 Series VacuFlush Toilet

Maintenance/Winterizing/Service

Note

Use nontoxic antifreeze designated for potable water systems . (See boat or vehicle

owner’s manual .)

Caution
Never use automotive-type antifreeze in freshwater systems .

7.8

Troubleshooting guide

Toilet base assembly

Sealing

Grommet

Check Valve

Electric Water

Valve

Filter

Screen

Drive Arm

Linkage

Flush

Spring

Circuit Board

Cam Switch

Rotor Shaft Cam

Flush Ball

Retaining Ring

Flush Ball Seal

Bowl Seal

Motor

SERVICE MODE

Toggle Switch

(alternate location

on some models)

Problem

Possible Cause

Service Instruction

1 . Water does not enter bowl

and toilet does not flush .

a . Toilet fuse or circuit breaker is

tripped .

b . Loose wire connections .

c . Incorrect wiring of toilet to

incoming power .

d . Defective circuit board .

a . To check toilet fuse, turn off

electrical power to toilet, wait 60

seconds, then turn on power to

toilet . Check circuit breaker at

main distribution panel .

b . Check for loose or defective wire

at circuit board pins 9 and 10 .

c . Check for reverse polarity of

incoming power .

d . Replace circuit board .

Advertising