Slant/Fin Gas Conversion Field User Manual

Page 16

Advertising
background image

16

Elevation - Feet

V-60 thru V-180

Sentry S-60 thru

S-150 & SX-150 thru

SX-210

TABLE 1

ORIFICE SIZE TABLE

SENTRY AND SENTINEL SERIES

VICTORY SERIES

GALAXY SERIES

2000

3000

4000

5000

6000

7000

8000

9000

10000

Natural

47

48

48

49

49

49

50

50

51

51

Propane

56

56

56

57

57

57

58

59

59

60

Natural

50

51

51

51

51

52

52

52

53

53

Propane

57

58

59

59

60

60

61

62

63

63

All Sentinel models and

Sentry S-34

Boiler

Model

Gas

Type

Orifice Sizes for High Altitudes

Includes 4% Reduction for Each 1000 Feet

Elevation - Feet

Orifice

Size

for

Sea

Level*

2000

3000

4000

5000

6000

7000

8000

9000

10000

Natural

48

49

50

50

50

51

51

52

52

52

Propane

56

56

56

57

57

57

58

59

59

6

Natural

50

51

51

51

52

52

52

52

53

53

Propane

57

58

59

59

60

60

61

62

63

63

V-33

Boiler

Model

Gas

Type

Orifice Sizes for High Altitudes

Includes 4% Reduction for Each 1000 Feet

Elevation - Feet

Orifice

Size

for

Sea

Level*

Orifice

Size

for

Sea

Level*

Gas

Type

Orifice Sizes for High Altitudes

Includes 4% Reduction for Each 1000 Feet

Boiler

Model

*

Orifice indicated for sea level above are factory installed in boiler unless

otherwise specified by the local authority.

See page 19 for burner input adjustment.

** For L.P. Propane consult factory.

Natural

49

50

50

50

51

51

51

52

52

52

Propane

57

58

59

59

60

60

61

62

63

63

2000

3000

4000

5000

6000

7000

8000

9000

10000

GG/GX Except

Natural

42

43

43

43

43

44

44

45

46

47

GG-399H & GG-350H

Propane

54

54

55

55

55

55

55

56

56

56

GG-399H

Natural

40

41

42

42

42

43

43

44

44

45

Propane

53

54

54

54

54

54

54

55

55

55

GXH-105

Natural

44

45

45

45

46

47

47

48

48

49

through 275

Propane

54

54

55

55

55

55

55

56

56

56

GXH-300

Natural

43

44

44

44

45

45

46

47

47

48

Propane

54

54

55

55

55

55

55

56

56

56

GXH-300H

Natural **

42

43

43

43

43

44

45

45

46

47

Gas Only

GXHA

Natural

45

46

47

47

47

48

48

49

49

50

Gas Only

55

55

55

55

56

56

56

56

56

57

VSP, VSPH, VH & VHS

VICTORY II - VHL, VHLS Series (Under 2000 Ft. Only)

Natural

49

Propane

57

VHL, VHLS

Boiler

Model

Gas

Type

Orifice

Size

for

Sea

Level*

SENTINEL SERIES

2000

3000

4000

5000

6000

7000

8000

9000

10000

Natural

47

48

48

49

49

49

50

50

51

51

Propane

56

56

56

57

57

57

58

59

59

60

Sentinel

Boiler

Model

Gas

Type

Orifice Sizes for High Altitudes

Includes 4% Reduction for Each 1000 Feet

Elevation - Feet

Orifice

Size

for

Sea

Level*

Advertising