DW800/820 Operation Manual

08

+5VDC

+5 Volt DC power

09

GND

Digital ground

10

SHIELD

Shield

The RS-232 interface connector is P3 on the circuit board

COMMUNICATIONS

Page 12

Output Formats

The DW800/820 is capable of transmitting one of the following formats: Optional Printer
Output Format (See Printer Section), Computer Output Format, and Scoreboard Output
Format. A format may be transmitted either on demand or continuously (See Parameter
Setup). Motion is tested only when transmitting the Printer Output Format on demand.

Computer Output Format

If the Computer Output Format is to be used then the Output Format parameter must be set to
CMP (See Parameter Setup).

The Computer Output Format is as follows:

STX Mode

Value

Pad

Status

Units CR

LF

Name

Characters Description

STX

1

ASCII Start of Text (02 Hex).

Mode

1

“G” if gross weight mode

1

“N” if net weight mode

1

“Q” if quantity (count) mode

Value

7

Displayed weight or quantity

Pad

1

ASCII Space (20 Hex)

Status

1
1

Units

3
3
3
4

“M” if scale is in motion
“0” if scale is in overload. ASCII Space (20 Hex) if scale is stable

“lb.” if in weight mode and unit is pounds. “kg” if in weight mode and unit is kilograms. “g” if in
weight mode and unit is grams, “pcs” if in count mode.

CR

1

ASCII Carriage Return (OD Hex)

LF

1

ASCII Line Feed (OA Hex)

_____________________________________________________________________________________________________________