DW800/820 Operation Manual

COMMUNICATION

Page 13

Scoreboard Output Format

If the Scoreboard Output Format is to be used then the Output Format parameter must be set
to SCB

(See Parameter Setup)

.

The Scoreboard Output Format is as follows: Value CR LF

Name

Characters

Description

Value

7

Displayed weight or quantity

CR

1

ASCII Carriage Return (0D Hex)

LF

1

ASCII Line Feed (0A Hex)

External Control

External Keys

The serial interface allows an external device to transmit data (external keys) to the
DW800/820, which mimic the keypad operation completely.

External Key

ASCII Value

Hex Value

Decimal Value

ZERO

a

81

097

PRINT

b

62

098

UNITS

c

63

099

TARE

d

64

100

GROSS/NET

9

67

103

PARAMETERS

z

7A

122

External Switch

An external switch is a hardware switch used to mimic a keypad operation completely. The
DW800/820 allows for only the ZERO external switch.

A momentary, normally open, switch must be connected between “Pin 01” and “Pin 09”.
External ZERO is activated when the switch is closed.
To avoid erratic operation the switch cable must be less than 10 feet.