DW800/820 Operation Manual

SPECIFICATIONS

Page 15

Operational

Internal Counts:

18,777,215

Display Counts:

10,000 recommended (50,000 maximum)

Display Update Rate:

10 times per second

Input Sensitivity:

0.5uV per graduation

Linearity:

0.01% of full scale

Overload Capacity:

105% of full scale

Load Cell Excitation:

10VDC (9,350 ohm load cells or 16,750 ohm load cells)

Calibration

Method:

Digital calibration

Range:

0.5 mV/V to 3.0 mV/V

Capacity:

2 to 500,000 lb., kg., or g

Display

Type:

6, 14 segment LCD with 20 annuniciators

Enunciators:

SCALE 1, 2, 3, 4 GROSS, NET, TARE k, g, lb., pcs,
SP3, SP2, SP1, LO BAT, M, -, ID,and ->0<-

Backlight:

Yellow/Green LED

Serial Interface

Type:

RS-232 (bi-directional, full-duplex)
*RS-422 (bi-directional, half-duplex)
*RS-485 (bi-directional, half-duplex)
*20mA Current Loop (transmit only)

Baud Rate:

Selectable from 150 to 19,200 bits per second

Parity:

Selectable from none, odd, or even

Data Bits:

Selectable from 7 or 8 bits

Start Bits

1

Stop Bits

1

Flow Control

Hardware flow control available for RS-232 only

Options

* Battery Operation