Software

Viewing Current Saf-T-Log Settings on Device

To view current settings on the Saf-T-Log Device without having to connect to the PC, turn the unit off Press
and hold the ‘On/Off’ (Backlight) button for three seconds and the current status will scroll across the center
of the screen including: date, time, user, Checklist name, and Saf-T-Log name/ID More information can be
viewed in the Instrument Menu (see pg 5 for more details)

If for instance you select ‘Day’ (as seen left) to save reports, a
new sub folder will be created whenever a report is saved on
a new day If ‘Checklist’ or ‘SAF-T device’ is used, the reports
will be filed according to matching checklists or Saf-T-Log
devices

Defaults for UK or US time format, °C or °F temperature units
and time zone can also be adjusted here for new Checklists
that may be created Click ‘Save Settings’ to keep the changes
Click ‘Cancel’ to discard changes

Changing Saf-T-Log Temperature Units (°F or °C)

The Saf-T-Log will display temperature on the device according to the temperature scale chosen for the
Checklist in the ‘Format Report’ tab To change the temperature units on the Saf-T-Log device, open the
Saf-T-Log software and open a Checklist to be saved to the Saf-T-Log device In the editing window, click
the ‘Format Report’ tab along the left sidebar Select ‘Reading (°F)’ or ‘Reading (°C)’ from the drop down
field in the center of the ‘Format Report’ screen to select the desired temperature scale Before the Saf-T-Log
device is updated with the desired temperature units, the Checklist must be sync’d to the Saf-T-Log device
by connecting the Saf-T-Log to the PC and while the Checklist is open in the editing window, selecting ‘Send
Checklist to Saf-T-Log’ Note: If multiple checklists are stored on the device, the temperature units (°F or °C)
for all checklists will default to the scale used on the first checklist stored.

View Current Readings on the Saf-T-Log Device

To view saved readings on the Saf-T-Log device before download, enter the Instrument Menu by pressing
both arrow buttons simultaneously Scroll to the ‘Saved Readings’ function and press the ‘Rec’ button Scroll
up and down to view the readings Press ‘Rec’ to exit