13. AUX connectors – L and R analog inputs, 300mV sensitivity. 
14. Non Sync (N/S) connectors – L and R analog inputs. 
15. RTA  microphone  –  3.5mm  stereo  jack  with  +10V  on  the  ring,  designed  for  use  with  a  powered  electret 

microphone. 

16. 8 Channel Analog Input on DB25F – Balanced line inputs.  Six channels are fixed (L, C, R, LFE, Ls, Rs) and two 

can be set up as either Lc/Rc or Lrs/Rrs. 

17. Public Address Microphone – Dual connector with XLR and ¼” phone jack in the center. 

 

6.5   

Thirty‐two Channel AES Output Rear Panel Connections (JSD‐100xD) 

A set of clip‐on ferrite “beads” is supplied with the JSD‐100.  To insure the JSD‐100 continues to meet FCC and CE 
radio emissions requirements, one of these beads should be clipped around each cable connected to the rear 
panel of the JSD‐100 except for the TOSLINK, AC Power, and Bypass Power connection. 
 

 

 

1. Bypass Power Supply – 12VDC at 1.25A. 
2. Power entry Module – Accepts IEC‐type line cord from 100‐240VAC power source.  Also contains a 500mA 

Slo‐Blo 5x20mm fuse. 

3. Thirty‐two Channel AES Output Module – Other modules include 8  and 16 channel analog.  

a. Control/Monitor  Connector  –  USL‐Link  for  remote  volume  and  other  functions  plus  amplifier 

monitor return and remote AES input. Monitor return is a future feature. 

b. Output channels 1 through 8 on four AES pairs. 
c. Output channels 9 through 16 on four AES pairs. 
d. Output channels 17 through 24 on four AES pairs. 
e. Output channels 25 through 32 on four AES pairs. 
f. Monitor and Bypass analog outputs. Monitor output not yet supported. 

4. Ethernet – Network communications with GUI, web browsers, automation, etc. 
5. RS‐232 on DE9F connector for communications with GUI or automation. 
6. Automation DB25F Connector – A bidirectional port for receiving and sending automation pulses between 

the  JSD‐100  and  other  system  components.    12  Control  lines,  11  Status  lines  and  +5V  are  provided.  
Standard pulse to ground system.   

7. SD Card ‐ stores the settings of the unit.  Can also be used to transfer settings to another unit. 
8. AES connector (DB25F) – Channels 1‐8 are standard.   Channels 9‐16 require the optional DI‐80 module. 
9. AES connectors (Dual RJ45s) – parallel connections to the DB25 above. 
10. TOSLINK Port – Optical Fiber input for SPDIF (PCM) or optional Dolby Digital®

 4 

decoding. 

11. COAX 1, COAX 2 ‐ RCA type connectors for SPDIF (PCM) or optional Dolby Digital®

 

decoding. COAX2 input 

is not supported with the 32 channel JSDR‐110 board. Instead, the COAX2 input becomes an AES input on 
the Control/Monitor connector (3a, above). 

12. Hearing Impaired/Visual Narration Outputs. 
13. AUX connectors – L and R analog inputs, 300mV sensitivity. 

                                                                 

4

 Manufactured under license from Dolby Laboratories. Dolby and the double‐D symbol are trademarks of Dolby Laboratories. 