USL JSD-100 Manual User Manual

Page 21

Advertising
background image

 

21 

 

either a JSD‐100 or JSD‐80 configuration file under “file type.”  If the JSD‐100 is replacing an existing JSD‐80, 
use the JSD‐80 GUI to save the configuration file if it is not available on the computer you’re using.  Then, with 
the JSD‐100 GUI, open the JSD‐80 configuration file. Common data, such as equalization, will be loaded into 
the JSD‐100.  

Save.  The “Save” button prompts you for the filename under which the configuration data is to be saved. 

Data can be restored to this or another unit using the Open button. 

 
Communications 
This group of buttons sets communications parameters between the GUI and the JSD‐100 and allows connections 
to be set up and taken down. 
 
Connect.  The GUI connects to the JSD‐100 specified in the Comm Settings dialog over the specified link. 
Disconnect.  The GUI disconnects from the currently viewed JSD‐100When the Disconnect button is pressed, 

the  GUI  will  ask  if  you  want  to  save  changes  to  the  JSD‐100.  When  “Save  Changes”  is  selected,  the  current 
configuration will be saved to flash memory and will be reloaded the next time the JSD‐100 is powered up. If 
“Save Changes” is not selected, the current configuration will not be saved or reloaded. Instead, the previous 
configuration will be loaded on the next power up. 

 
Comm Settings 
Press this button to configure the communications link to the JSD‐100. The JSD‐
100 GUI can communicate with the JSD‐100 over Ethernet (TCP/IP), USB, or RS‐
232. Click on the appropriate tab for this unit. If you find the GUI on occasion 
disconnects  from  the  JSD‐100,  try  clicking  the  Advanced  button  and  increase 
each of the timeout values. This may be required on a slow network. 
 
TCP/IP 
Check "Display automatically detected network devices" to get a list of JSD‐100 
units the GUI can find on the network. Any device ever found is listed (they do 
not  disappear  if  they  have  not  been  heard  from  in  a  while).  Select  the 
appropriate unit from the list or click "Manual Add" to specify an IP address for 
a JSD‐100. Use the "Remove" button to remove a displayed unit from the list. 
Once the desired unit is selected, press OK to exit the dialog. 
 
USB 
Select  this  tab  to  connect  to  the  JSD‐100  using  USB.  When  the  host  computer  is  connected  to  the  JSD‐100  USB 
port, the JSD‐100 should be listed under the device list. If the "Connect to first available USB device" is checked, 
the first device (and probably the only device) on the list will be selected. If it is not checked, select the appropriate 
device, and then click OK. 
 
RS‐232 
Select the COM port the JSD‐100 is connected to, and then click OK. 
 
Unit Settings 
This group of buttons handles a few “system wide” system configuration settings and backing up those settings.   
 
Date and Time 
This button sets the time and time zone information in the JSD‐100.  The JSD‐100 
itself  only  uses  time  of  day  in  logging.      Further,  all  log  entries  are  made  in  UTC.  
When viewed through the GUI, log data includes the time in UTC, the time at the 
JSD‐100  (JSD  Time),  and  the  time  at  the  GUI  (GUI  Time).  The  use  of  these  three 
time zones allows for simple comparison of device logs, even when the devices are 
in multiple time zones. The Date and Time dialog allows setting of date and time 

Advertising