Global Tab 
Global settings, those that do not 
change  with  format  or  EQ  set, 
are set or displayed here.  
 

Unit Time 
The time settings in the unit can 
be observed in this section of the 
tab.  These  settings  are  set  using 
the  Date  &  Time  button  at  the 
top of the screen.  The Unit Time 
data  includes  the  current  UTC 
value  in  the  JSD‐100  real  time 
clock,  the  time  zone  offset  from 
UTC  for  standard  time,  the 
abbreviations for standard and daylight saving time, and whether daylight saving time is observed at this location.  
 
Network Time Protocol 
This section also allows the IP address of the Network Time Protocol server to be set and enabled or disabled. If an 
NTP server is available on the network, enter its IP address, check NTP Enable, and press the Set IP button. 
 
Sleep Settings 
The JSD‐100 includes a sleep timer. The timer is reset to its timeout value on any format change, any fader level 
change, or any audio output above ‐20dB (referenced to 300mV RMS). If, for example, the sleep timeout is set to 1 
hour, the system will go to sleep 1 hour after the last format change, level change, or audio. When the system goes 
to  sleep,  power  consumption  is  decreased  from  about  18W  to  about  7.5W.    The  system  wakes  up  on  a  format 
change, a level change or a specific command over Ethernet (See Appendix B). Audio presence will not wake the 
system up since the audio circuitry is shut down during sleep. The current sleep timer value is shown. The unit will 
go to sleep in the displayed number of hours and minutes. To set the sleep timeout, key in the number of hours 
and minutes or use the arrows to change the Sleep Timeout value. Once the value is entered, press Set Timeout to 
save the value in the JSD‐100. If sleep is not to be used, check Disable Sleep Timer and press Set Timeout.  
 
SNMP Community Settings 
This  section  allows  the  Write  and  Read  community  settings  to  be  viewed  or  changed.  The  JSD‐100  does  not 
currently use the write community setting since the JSD‐100 cannot be controlled over SNMP, only monitored. 

 

Remote Fader Settings 
This section allows the display timeout on remote volume controls to be set. Use the slider to set the number of 
seconds after an adjustment that the remote volume display will blank. Setting the timeout value to zero prevents 
the display from blanking. 
 

Unit Status 
This  portion  of  the global  tab  shows  the  temperature  within  the  JSD‐100,  whether  the  optional  DI‐80  and  DI‐84 
board are present, and the status of AES inputs. The DI‐80 board is required for 16 channel digital input. Without 
it,  the  AES  input  is  8  channels.  The  DI‐84  board  is  required  to  decode  Dolby  Digital®  from  two  channel  inputs. 
When the Get AES Status button is pressed, the AES Channel Status indicators are updated. Green indicates the 
parameter is true. Red indicates it is false. Gray indicates it cannot be determined.  
 