Operation – Vogelzang VG5770 User Manual

Page 15

Advertising
background image

15

Operation

chimney.
You should adjust the damper based on the fi re’s appearance. A low, reddish, dirty fi re can be improved by turning the
dampener slightly to the right. A “blow torch” fi re can be improved by turning the dampener to the left a little bit.
As a general rule, on lower feed rate settings, the damper should be farther to the left closing it off. On higher feed
rates, the damper should be open more by having it set more towards the right. Through trial and error, you will fi nd
the best setting. Consult your dealer if you need help.
NOTE: On heat range “1”, damper should be either completely closed or open no more than a ¼ of the way. If damper
is open to far, it can cause the fi re to go out.

OPENING DOOR

If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If
the stove shuts down push the “On/Off” button to re-start your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually
takes about 10 minutes from start-up.

IF STOVE RUNS OUT OF PELLETS

The fi re goes out and the auger motor and blowers will run until the stove cools. This will take 30 minutes or longer
depending on the heat remaining in the appliance. After the stove components stop running all lights on the display
will go out and the two digit display will begin fl ashing “E3”

REFUELING

The hopper and stove top will be hot during operation; therefore, you should always use some type of hand pro-
tection when refueling your stove.

Never place your hand near the auger while the stove is in operation.

We recommend that you not let the hopper drop below ¼ full.

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING.

DO NOT OVERFILL HOPPER.

SHUTDOWN PROCEDURE

Turning your stove off is a matter of pressing the “POWER” button on the display board. The green light will turn back
to red when the “POWER” button is pushed. The auger motor will stop, and the blowers will continue to operate until
the internal fi rebox temperatures have fallen to a preset level.

1. Your stove is equipped with a high temperature thermodisc. This unit has a manual reset thermodisc. This safety

switch has two functions.

A. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut
down the auger, preventing the stove from overheating.

NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The
manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem. A ser-
vice call may be required.

2. If the combustion blower fails, an air pressure switch will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. The stove will shut down and show “E2” on the two digit display. The
stove has to fully shut down before restarting.

WARNING: Never shut down this unit by unplugging it from the power source.

Advertising