Engine care, Generator care, Grounding – Winco EC22000/A User Manual

Page 10

Advertising
background image

224-00

8

60706-23

nameplates. When in doubt consult the manufacturer

or a local electrician. The nameplate amperage rat-

ing for electric motors can be misleading. See “Start-

ing Electric Motors” in Unit Capabilities (page 4).

These engine-generator sets are inherently self regu-

lating based on engine speed. The engine governor

will automatically adjust itself to the load. No harm

to the generator will result if it is operated with no

load connected. The generator is a limited source of

electrical power, therefore pay special attention to the

generator ratings.

GROUNDING

All units must be properly grounded. Different instal-

lations will require different grounding requirements.

Depending on your installation ensure that the

ground meets your governing codes.

ENGINE CARE

If major engine service or repair is required contact

an authorized engine service center. The manufac-

turer of these engines has established an excellent

world-wide engine service organization. Engine ser-

vice is very likely available from a nearby authorized

dealer or distributor. Check the yellow pages of your

local telephone directory under “Engines-Gasoline”

for the closest engine repair center or ask the dealer

from whom you purchased the power plant.

.

Change the oil after the first month or 5 hours of

operation and every 2 months or 00 hours there-

after under normal operating conditions. Change

engine oil every 50 hours of operation if the engine

is operated under heavy load, or in high ambient

temperatures.

a. Remove oil drain plug at base of the engine

and drain the oil with the engine warm.

b. Replace oil drain plug.

c. Remove oil filler plug and refill with new oil.

Refer to the table in the engine manual for

the proper grade of oil based on your

operating temperature.

d. Replace filler plug.

2.

Checking the Oil Level: The oil level must al-

ways be checked before the engine is started. Take

care to remove any dirt or debris from around the

oil fill plug before removing. Be sure the oil level is

maintained. Fill to the “

FULL” mark on the dipstick.

3.

Dual Element Air Filter: Clean and/or replace

foam pre-cleaner and air filter every 12 months or

00 hours. Service more often under dusty condi-

tions.

a. Loosen screws and remove cover and air

cleaner assembly from base.

b. Remove foam pre-cleaner by sliding it off the

paper cartridge.

c. Wash foam pre-cleaner in liquid detergent

and water.

d. Wrap foam pre-cleaner in cloth and squeeze

dry.

e. Saturate foam pre-cleaner in engine oil.

Squeeze to remove excess oil.

f. Clean Air filter.

g. Install foam pre-cleaner over air filter.

h. Re-install the Air Filter assembly.

Reassemble cover and screw down tight.

Do not use petroleum solvents, such as kerosene,

to attempt to clean the cartridge. They may cause

deterioration of the cartridge. DO NOT OIL CAR-

TRIDGE. DO NOT USE PRESSURIZED AIR TO

CLEAN OR DRY CARTRIDGE.

4.

Spark Plug: Clean and reset gap at .030” every

2 months or 00 hours of operation. Do not blast

clean spark plug. Clean by scraping or wire brush-

ing and washing with a commercial solvent. Poor

spark will occur if terminal does not fit firmly on spark

plug. If this happens reform the terminal to fit firmly

on spark plug tip.

5.

Carbon Canister: Designed to collect, store,

and dispose of fuel vapors created in the fuel tank /

fuel system. Remove and clean or replace the filter

on the canister when maintaining your air filter. The

canister will last the life of the unit.

GENERATOR CARE

Proper care and maintenance of the generator is

necessary to ensure a long trouble free life.

.

Exercising The Generator - The generator

should be operated every three to four weeks. It

should be operated for a period of time sufficient to

warm the unit up and to dry out any moisture that

has accumulated in the windings. If left, this mois-

ture can cause corrosion in the winding. Frequent

operation of the engine generator set will also

ensure that the set is operating properly should it be

needed in an emergency.

Advertising