Lubrication, Battery installation, Battery charging – Winco EC22000/A User Manual

Page 7: Oil alert system, Initial start up

Advertising
background image

5

60706-23

224-00

LUBRICATION

Before starting the engine, fill the crankcase to the

proper level with a good quality oil. The recom-

mended grade of oil and quantity of oil required is

listed in the engine operator’s manual. The neces-

sity of using the correct oil and keeping the crank-

case full cannot be overemphasized. Engine failures

resulting from inadequate or improper lubricant are

considered abuse and not covered by the generator

or engine manufacturer’s warranty.

BATTERY INSTALLATION

You will need to connect this unit to a battery to

operate it. Cables have not been provided as length

are going to vary depending on your installation.

These engines are all negative ground. The posi-

tive battery cable must be connected to the open

large terminal on the start solenoid (This terminal

may have a small 6 GA. wire on it for the charging

circuit). The negative cable should be attached to a

good ground on the engine. This is usually one of

the starter mounting studs.

A twelve volt battery, rated at 300 CCA or larger is

recommended for this electric start engine generator

set. Follow the battery manufacturer’s recommenda-

tions for servicing and charging prior to use.

CAUTION: EQUIPMENT DAMAGE

These electric start engines are NEGATIVE

GROUND. Use extreme caution when connecting

the battery. Connect the NEGATIVE battery terminal

to GROUND.

For your safety always connect the positive battery

cable to the “BAT+” terminal first. Then connect the

negative battery cable to the “BAT-” terminal. Make

sure all connections are clean and tight. Reverse

the sequence when disconnecting, disconnect the

negative cable first. These engines produce enough

direct current to keep a battery charged under nor-

mal operating conditions, but were not intended to

be used as a battery charger.

WARNING: PERSONAL INJURY

Lead acid batteries produce explosive hydrogen gas

when charging. Keep sparks, flames, and burning

cigarettes away from the battery. Ventilate the area

when charging or using the battery in an enclosed

space. Lead acid batteries contain sulfuric acid,

which causes severe burns. If acid contacts eyes,

skin or clothing, flush well with water. For contact

with eyes, get immediate medical attention.

BATTERY CHARGING

Units equipped with electric start have a small fly-

wheel charger built into the engine flywheel assem-

bly for recharging the starting battery. This flywheel

charger generates a small AC current that passes

through a diode assembly to produce a DC charg-

ing current of about  to 3 AMPS. This circuit is not

designed to be used as a battery charging circuit to

recharge dead batteries.

OIL ALERT SYSTEM

These engine generator sets come equipped

standard with the Briggs & Stratton low oil pressure

shutdown system. The low oil shutdown system is

designed to prevent severe damage caused by an

insufficient amount of oil in the crankcase. However

if the unit is repeatedly allowed to shutdown on low

oil pressure progressive damage will be done to

the engine shortening the engine’s life. The engine

switch will remain in the “ON” position when the unit

is shutdown by the low oil pressure system.

INITIAL START UP

The throttle control on these generators is preset

and locked to operate at 3600 RPM (nominal) with

no load speed set at 3690 RPM. Only a trained

service technician should be allowed to adjust this

speed setting.

NOTICE: ENGINE START LOCKOUT

This unit

will not start and run if it is low on oil.

The lubricating oil level must be at the

full mark

before the engine will start and run.

Advertising
This manual is related to the following products: