9

60706-23

224-00

2.

Generator Maintenance - Any major generator

service including the installation or replacement of

parts should be performed only by a qualified electri-

cal service technician.

USE ONLY FACTORY AP-

PROVED REPAIR PARTS.

a. Bearing - The bearing used in these

generators is a heavy duty double sealed ball

bearing. They require no maintenance or

lubrication.

b. Receptacles - Quality receptacles have been

utilized. If a receptacle should become

cracked or otherwise damaged, replace it.

Using damaged or cracked receptacles can be

both dangerous to the operator and destructive

to the equipment.

CLEANING

Remove dirt and debris with a cloth or brush. DO

NOT use high pressure spray to clean either the

engine or the generator. This high pressure spray

could contaminate the fuel system and the generator

components.

. Keep the air inlet screen on both the engine and

generator free of any dirt or debris to ensure proper

cooling. At least yearly remove the blower housing

on the engine and clean the chaff and dirt out of the

engine cooling fins and flywheel. Clean more often

if necessary. Failure to keep these areas clean may

cause overheating and permanent damage to the

unit.

2. Periodically clean muffler area to remove all

grass, dirt and combustible debris to prevent a fire.

3. On engine mufflers equipped with spark arresters,

the spark arrester must be removed every 50 hours

for cleaning and inspection. Replace if damaged.

TROUBLESHOOTING

HINTS

PROBLEM (SYMPTOMS) POSSIBLE CAUSES

———————————————————————

Won’t Start

*Low Oil Level.

*Fouled spark plug.

*Out of fuel.

*Start switch in Off position.

———————————————————————

Voltage too low

*Engine speed is too low.

*Generator overloaded.

*Defective stator.

*Defective rotor (field).

———————————————————————

Circuit Breaker

*Defective load.

Trips

*Defective receptacle.

———————————————————————

Voltage too high

*Engine speed is too high.

———————————————————————

Generator

*Overloaded.

overheating

*Insufficient ventilation.

———————————————————————

No output voltage

*Short in load (disconnect).

*Broken or loose wire.

*Defective receptacle.

*No residual magnetism

(in generator).

*Defective stator.

*Defective rotor (field).

*Shorted capacitor.

*GFCI Receptacle tripped.

———————————————————————