Installation and unit preparation, Ventilation, Gasoline – Winco EC22000/A User Manual

Page 6

Advertising
background image

224-00

4

60706-23

INSTALLATION AND UNIT

PREPARATION

It is the customer’s responsiblilty to ensure

that all installations comply with all local,

state and national codes, including OHSA,

EPA and NEC.

CAUTION EQUIPMENT DAMAGE

These units must be mounted on a solid surface to

prevent the unit from vibrating and causing damage

to the engine or generator.

Before beginning the installation process recheck

the rating of the generator to be certain it can handle

the intended load. Plans for installation should be

prepared with proper attention to mechanical and

electrical engineering detail to assure a satisfactory

system installation. The information in this manual is

offered only as a guide to finalizing your installation

plans. As each installation is different no specifics

are provided in this manual

VENTILATION

These engine generator sets use large amounts of

fresh air for cooling. When designing plans for your

installation special attention must be paid to the flow

of hot air from both the engine and the generator.

Both the engine and the generator must be supplied

with a constant flow of fresh air from the outside to

ensure they don’t overheat. Some provision must be

made to remove the hot air out of the enclosure. Am-

bient temperature around the unit should not exceed

22

0

F. Engine or generator failures resulting from

inadequate ventilation are considered abuse and not

covered by the generator or engine manufacturer’s

warranty.

The engine exhaust from this engine must be vented

to the outside. When venting hot exhaust through

any type of flammable wall be sure to use exhaust

thimbles to prevent fires.

WARNING: PERSONAL INJURY

Failure to properly vent the exhaust out of an enclo-

sure can and will kill you. Carbon monoxide is both

invisible and orderless and can build up very rapidly

in any enclosure not properly vented.

GASOLINE

When using gasoline always use a good grade of

unleaded fuel. This engine is certified to operate on

unleaded gasoline with a pump octane rating of 86

or higher. Gasoline containing no more than 0%

ethanol (E10) or 5% methanol by volume may be

used. In addition methanol must contain co-solvents

and corrosion inhibitors. Use of fuels with content

of ethanol or methanol greater than shown above

may cause starting and/or performance problems.

Always ensure that the fuel is clean and free of all

impurities.

WARNING: FIRE DANGER

Gasoline and its fumes are VERY explosive when

proper precautions are not taken.

Never use gasoline that has been stored for an ex-

tended period of time as the fuel will lose its volatile

properties and you will be left with only the varnish

residue. This varnish like substance will clog the

carburetor and will not burn properly.

The use of fuel additives, such as STA-BIL, or an

equivalent will minimize the formation of fuel gum

deposits. If a unit has been out of operation for an

extended period of time it is best to drain old fuel

from the engine and replace with fresh fuel before

attempting to start.

These units have been designed and shipped with-

out fuel tanks. This allows the customer to utilize

whatever size and type of tank they may desire, with

some limitations.

. The fuel lift from the bottom of the tank to the

fuel inlet on the generator must not exceed 3 feet.

If a greater lift is required it may be necessary to

provide an additional electric fuel pump to ensure

the engine gets a sufficient flow of fuel.

2. Some states require the installation of a carbon

canister on the tank vent line. This is to prevent the

escape of fuel vapors in to atmosphere.

3. You need to have is a primer bulb in the fuel line

to prime the fuel from the tank to the fuel pump.

The vacuum fuel pump on the engine will not draw

the fuel up from the tank until the line has been

properly primed.

4. In all cases the minimum fuel line size must be

1/4” or larger line. And the fuel line must be certified

for use with unleaded gasoline.

Advertising