Fig. 4 - suggested rigging, Step 5 — connect condensate drain, Table 1 — physical data (cent) – Carrier 48NLT User Manual

Page 5: Do not undersize the tube

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 1 — Physical Data (cent)

UNIT SIZE 48

NLT

042

NMT

042

NET

042

NHT

042

NVT

042

NLT

048

NMT

048

NHT

048

NVT

048

NLT

060

NMT

060

NHT

060

NVT

060

NOMINAL CAPACITY (ton)

3Vz

4

5

OPERATING WEIGHT (lb)

496

500

500

550

556

574

580

586

586

604

610

616

616

COMPRESSORS

Quantity______

Reciprocating Hermetic, 3500 Rpm

1

REFRIGERANT*

R-22

REFRIGERANT METERING

DEVICE

AocuRater® Piston

CONDENSER COIL

Rows
FIns/ln.

2

20

CONDENSER FAN

Nominal Airflow (Cfm)
Nominal Speed (Rpm)

Quantlty...Dlameter (In.)
Motor Hp (single-phase)

(three-phase)

2500

3000

3500

EVAPORATOR COIL

Rows
Fins/ln._________

EVAPORATOR FAN

Nominal Cfm
Nominal Speed (Rpm)
Diameter x Width (In.)

Motor Hp (single-phase)

(three-phase)

FURNACE SECTION

Burner Orifice No.

(Qty...drlll size) Natural Gas

Burner Orifice No.

(Qty...drill size) Propane Gas

Pilot Orifice Diameter

(In. ...drill size) Natural Gas

Pilot Orifice Diameter (In.)

Propane Gas

2000

I

3450

V2

3/4

’/2

3/4

3 44

4. 44

4 42

5 44

6 44

3 44

4 44

5 44

6 42

3 44

4 44

5 44

6 42

3 55

4 55

4 54

5 55

6. 55

3 .55

4 55

5 55

6 54

3 55

4 55

5 55

6 54

018 77

009

RETURN-AIR FILTERS (sq ln.)t

Disposable

720

816

960

Cleanable

480

544

640

•Operating charge is iisted on unit namepiate
tRequired fieid-suppiied fiiter areas are based on the iarger of the ARi-rated (Air Conditioning & Refrigeration institute) cooling airflow or the heating airflow at a velocity of 300 ft/min

for disposable type or 450 ft/min for high-capacity type. Air filter pressure drop must not exceed 0 08 in wg

Step 5 — Connect Condensate Drain

NOTE: When installing condensate drain connection be sure
to comply with local codes and restrictions.

The unit disposes of condensate water through a %-in.

NPT drain fitting. See Fig. 2 and 3 for location.

Install a 2-in. trap at the drain fitting to ensure proper

drainage. See Fig. 5. Make sure the outlet of the trap is at
least one-in. lower than the unit drain pan connection to

prevent the pan from overflowing. Prime the trap with
water.

If the installation requires draining the condensate water

away from the unit, connect a drain tube using a minimum
of %-in. OD copper tubing, y4-in. galvanized pipe or %-in.
plastic pipe.

Do not undersize the tube.

Pitch the drain tube

downward at a slope of at least one inch in every 10 ft of
horizontal run. Be sure to check the drain tube for leaks.

UNIT 48

CORNER WT (LB)

A

B

C

D

NLT018

99

126

126

99

NLT024

100

127

127

100

NHT024

101

129

129

101

NLT030

103

132

132

103

NMT030

105

133

133

105

NHT030

106

134

134

106

NLT036

107

136

136

107

NMT036

108

137

137

108

NET036

108

137

137

108

NHT036

117

147

148

118

NVT036

119

148

149

120

NLT042

109

139

139

109

NMT042

110

140

140

110

NET042

110

140

140

110

NHT042

117

147

147

117

NVT042

124

153

154

125

NLT048

128

158

159

129

NMT048

130

159

160

131

NHT048

131

161

162

132

NVT048

131

161

162

132

NLT060

136

165

166

137

NMT060

138

166

167

139

NHT060

139

168

169

140

NVT060

139

168

169

140

Fig. 4 - Suggested Rigging