Carrier WEATHERMASTER 48ZT User Manual

Installation instructions

Advertising
background image

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53480060-01

Printed in U.S.A.

Form 48Z-8SI

Pg 1

4-09

Replaces: 48Z-7SI

Installation Instructions

CONTENTS

Page

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . . .1,2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59

Jobsite Survey

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Unit Placement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Roof Mount

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Slab Mount

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Curb Gasketing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Field-Fabricated Ductwork

. . . . . . . . . . . . . . . . . . . . . . . 2

Rigging

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Condensate Drain Connections

. . . . . . . . . . . . . . . . . 23

Install Outdoor Hoods

(48ZG,ZN,Z6,Z8 Units)

. . . . . . . . . . . . . . . . . . . . . . . . . 33

• UNIT SIZES 030-050

• UNIT SIZES 055-105
Install Economizer Hoods (48ZT,ZW Units)

. . . . . . 35

• INSTALL SMALL HOODS

• INSTALL LARGE HOODS
Field Wire Routing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

• UNIT SIZES 030-050

• UNIT SIZES 055-105
Field Electrical Connections

. . . . . . . . . . . . . . . . . . . . 36

• POWER WIRING
Air Pressure Tubing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

• INLET GUIDE VANES

• VARIABLE FRQUENCY DRIVE

• MODULATING POWER EXHAUST

• RETURN/EXHAUST POWER EXHAUST
Supply-Fan Shipping Brackets

. . . . . . . . . . . . . . . . . . 53

• UNIT SIZES 030-050

• UNIT SIZES 055-070

• UNIT SIZES 075-105
Return/Exhaust Fan Shipping Brackets

(48Z6,Z8 Units)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Remove TXV Shipping Blocks

. . . . . . . . . . . . . . . . . . . 54

Compressor Mounting

. . . . . . . . . . . . . . . . . . . . . . . . . . 55

Gas Piping

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Optional Staged Gas Control

. . . . . . . . . . . . . . . . . . . . 55

Installing Flue/Inlet Hoods

. . . . . . . . . . . . . . . . . . . . . . 56

Supply Air Thermistors

(Staged Gas Units Only)

. . . . . . . . . . . . . . . . . . . . . . 56

Install Unit Accessories

. . . . . . . . . . . . . . . . . . . . . . . . . 59

CONTROLS INSTALLATION

. . . . . . . . . . . . . . . . . . 59-66

Constant Volume Units

. . . . . . . . . . . . . . . . . . . . . . . . . . 59

• CONTROL WIRING
Variable Air Volume Units

. . . . . . . . . . . . . . . . . . . . . . . 59

Optional and Accessory Control Wiring

. . . . . . . . . 60

Carrier Comfort Network

®

(CCN) Interface

. . . . . . . 60

Smoke Control Modes

. . . . . . . . . . . . . . . . . . . . . . . . . . . 61

GENERAL

This installation instruction contains basic unit installation

information, including installation of thermostats and remote

temperature sensors.

For additional information and service instructions, refer to

the Controls and Troubleshooting literature also enclosed in

this literature packet.

The 48ZT,ZW units are equipped with standard integral

economizer and high-capacity power exhaust.

The 48Z6,Z8 units are equipped with factory-installed

return/exhaust fans.

The staged gas control (SGC) option adds the capability to

control the rooftop unit’s gas heating system to a specified sup-

ply air temperature set point for purposes of tempering a cool

mixed-air condition.

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can

be hazardous due to system pressure and electrical compo-

nents. Only trained and qualified service personnel should

install, repair, or service air-conditioning equipment.

Untrained personnel can perform basic maintenance func-

tions of cleaning coils and filters and replacing filters. All

other operations should be performed by trained service per-

sonnel. When working on air-conditioning equipment, observe

precautions in the literature, tags and labels attached to the unit,

and other safety precautions that may apply.

Follow all safety codes, including ANSI (American Nation-

al Standards Institute) Z223.1. Wear safety glasses and work

gloves. Use quenching cloth for unbrazing operations. Have

fire extinguisher available for all brazing operations.

WARNING

Before performing service or maintenance operations on

unit, turn off main power switch to unit. Electrical shock

could cause personal injury.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance. Do not touch any electri-

cal switch; do not use any phone in your building. Immedi-

ately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions. If you cannot reach

your gas supplier, call the fire department.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

WARNING

Improper installation, adjustment, alteration, service, or

maintenance can cause injury or property damage. Refer to

this manual. For assistance or additional information, con-

sult a qualified installer, service agency, or the gas supplier.

WEATHERMASTER

®

48ZG,ZN030-105

48ZT,ZW,Z6,Z8075-105

Single Package Gas Heating and Electric Cooling Units

with Direct Spark Ignition and COMFORTLINK™ Controls

Advertising
This manual is related to the following products: