Table 8 — Dry Coil Air Delivery (Cfm)*

at Indicated External Static Pressure and Voltage

— Horizontal Discharge (Without Filter)

48

V-PH-HZ

MOTOR

SPEED

208 V

230 V or 460 V

in. wg

0.0

0.1

0.2

0.3

0.4

0.5

0.0

0.1

0.2

0.3

0.4

0.5

NLT018, NLT024,
NHT024
208/230-1-60

Lowf,
Med“

Watts

451

427

407

383

365

348

501

477

457

433

415

398

Cfm

1185

1129

1088

1026

979

922

1256

1195

1148

1081

1031

971

HI

Watts

511

483

464

440

420

402

561

533

514

490

470

452

Cfm

1370

1291

1221

1142

1063

1003

1442

1359

1285

1202

1119

1056

NLT030, NMT030

208/230-1-60

Lowf,
Med“

Watts

519

507

492

477

455

431

569

557

542

527

505

481

Cfm

1184

1163

1150

1134

1105

1064

1248

1226

1211

1194

1164

1120

Hi

Watts

620

602

581

559

532

493

670

652

631

609

582

543

Cfm

1443

1414

1376

1329

1279

1197

1519

1489

1449

1399

1347

1261

NHT030, NLT036
NMT036, NLT042
NMT042
208/230-1-60
208/230-3-60,

460-3-60tt

Lowf,
Med“

Watts

560

544

527

505

482

461

610

593

575

500

524

494

Cfm

1515

1452

1389

1308

1227

1105

1597

1530

1464

1378

1293

1164

Hi

Watts

670

650

631

602

573

542

720

701

680

653

625

594

Cfm

1765

1705

1621

1521

1383

1254

1857

1795

1708

1603

1457

1321

NET036, 042
208/230-1-60
208/230-3-60

460-3-60tt

Lowf,
Med“

Watts

873

847

814

785

758

734

987

945

911

877

850

809

Cfm

1717

1690

1645

1597

1550

1496

1979

1922

1859

1802

1734

1667

Hi

Watts

1075

1030

995

960

930

900

1121

1087

1046

1017

981

952

Cfm

2119

2062

1995

1913

1863

1793

2135

2066

1998

1931

1858

1795

NHT036, NVT036
NHT042, NVT042
208/230-1-60
208/230-3-60

460-3-60tt

Lowf,
Med“

Watts

740

700

660

615

580

540

755

725

680

650

610

575

Cfm

1913

1820

1736

1645

1544

1428

1976

1909

1806

1714

1603

1495

Hi

Watts

790

760

720

690

650

610

850

820

780

750

715

675

Cfm

2032

1942

1844

1759

1636

1514

2086

1983

1883

1782

1665

1545

NLT048, NMT048
NHT048

208/230-1-60
208/230-3-60

460-3-60tt

Lowf,
Med“

Watts

770

730

690

650

610

575

810

765

730

695

655

610

Cfm

1945

1880

1796

1708

1611

1508

2061

1970

1892

1813

1704

1580

Hi

Watts

850

810

770

730

690

655

890

855

820

780

750

715

Cfm

2138

2045

1943

1846

1738

1624

2178

2081

1941

1869

1769

1650

NVT048

208/230-1-60
208/230-3-60

460-3-60tt

Lowf,
Med“

Watts

985

950

915

890

860

820

1095

1055

1010

975

935

890

Cfm

1931

1901

1862

1813

1768

1703

2183

2125

2071

2005

1931

1854

Hi

Watts

1220

1165

1130

1080

1035

995

1300

1265

1220

1180

1120

1085

Cfm

2376

2311

2244

2170

2083

2003

2511

2431

2359

2271

2168

2087

NLT060, NMT060
NHT060, NVT060
208/230-1-60

208/230-3-60

460-3-60tt

Lowf,
Med“

Watts

1125

1055

1015

980

940

905

1205

1125

1095

1060

1030

990

Cfm

2184

2125

2063

2000

1938

1880

2285

2225

2163

2106

2045

1980

Hi

Watts

1220

1175

1125

1080

1040

1005

1300

1250

1210

1165

1130

1085

Cfm

2380

2307

2262

2165

2095

2024

2487

2412

2335

2260

2179

2110

*Air delivery values are without air filter and are for dry coil. See Table 10 for wet coil pressure drop.

Deduct field-supplied air filter pressure drop and wet coil pressure drop to obtain external static
pressure available for ducting.

tFactory blower-motor speed setting for heating operation.

‘'Factory blower-motor speed setting for cooling operation.

ttDo not change blower speed settings for units with 460-v (high speed only).

NOTE: Do not operate the unit at a cooling airflow that is less than 350 cfm per each 12,000 Btuh of
rated cooling capacity. Evaporator coil icing may occur at airflows below this point. Water blow-off may
occur at airflows above 450 cfm per 12,000 Btuh of rated cooling capacity

The heating and/or cooling airflow of 208/230-v direct-
drive blower motors can be changed by changing the lead
connections of the blower motor. The motor leads are color-

coded as follows:

black

=high speed

blue

= medium speed

red

=low speed

NOTE: For all 208/230-v direct-drive units, the red motor
lead connected to the heat relay (L) on PCI blower control
determines the heating speed and resulting airflow, and the
blue motor lead connected to the cooling relay (H) on PCI
blower control determines the cooling speed and resulting
airflow. See the unit wiring label.

To change the heating and/or cooling speed of a direct-

drive motor, connect the appropriate color-coded lead at blower
motor connector to speed-tap desired. (See unit wiring
label.)

When installing a 208- or 230-v direct-drive unit that is

factory connected for heating and cooling speeds that are
not the same, and the same speed for both heating and cool­
ing is required for a particular application, disconnect red

lead at terminal L of heat relay and connect to terminal MI
on PCI blower control. Connect a field-supplied jumper be­
tween terminal L on heat relay and terminal H of cooling

relay. Connect blue lead at blower motor to appropriate speed
tap.

18