MOUNT

OUTDOOR

THERMOSTAT(S)

Locate maximum of 2 outdoor thermostats in the

compressor section on the partition to the left of the

reversing valve. Fasten with sheet metal screws using

engagement holes provided. Uncoil a short length of
capillary and insert bulb into rubber grommet in the

partition. Moisten bulb to assist insertion. Insert all
but 1 in. of bulb. Secure remaining capillary.

MOUNT EMERGENCY HEAT REEAY in the

compressor section on the partition to the left of the

reversing valve using engagement hole provided.

Fasten with sheet metal screws.

To Start Unit

— Check that main power is on and

that compressor crankcase heater has been ener­

gized for at least 24 hours.

1. Check that heater main power is on as applicable.

2. Set selector switch at OFF.

3. Set fan switch as desired (FAN) (AUTO.).

4. Set thermostat dial at the desired temperature.

5. Set selector switch at HEAT or COOL. Check

system refrigerant charge. See Refrigerant
Charging.

Unit

Single-Phase

Compressors

that

are

Equipped with a Compressor Start Thermistor
(PTC device) (024,030,036)

— When supply

voltage is within 10% limit and compressor does not
start, check the start thermistor with an ohmmeter.

CHECKING START THERMISTOR

1. Shut off all power to unit and wait 10 minutes

for thermistor to cool to ambient temperature.

2. Remove thermistor from circuit.

3. Measure resistance of thermistor with ohm-

meter. Normal resistance readings are 25 ohms

± 20% at 75 F ambient temperature.

4. If ohmmeter resistance reading is not within the

± 20%, the thermistor is defective and must be

replaced.

THERMOSTAT

a

SUBBASE

(SEE BELOW)

50YQ UNIT

CONTROL WIRING

TERMINAL BOX

CHANGEOVER

Automatic

Manual

Manual

Automatic

___SUBBASE

J-IH93AZ073

HH93AZ075

Subbase included

Subbase included

THERMOSTAT

HH07AT071

HH07PZ085

HH07PZ08^6

COOLING AND ONE-STAGE HEATING

(without Electric Heater)

THERMOSTAT

a

SUBBASE

(SEE BELOW)

50Y0 UNIT

CONTROL WIRING

TERMINAL BOX

R -

G —

Y -

0 --

-- R

- G

- Y

0

E —

INSTALL

r '

JUMPER

-W3 —

L

-VI0-(HRI

-0RN-(HR3

-BRN

HR — Heater Relay

THERMOSTAT

a

SUBBASE

(SEE BELOW)

50YQ UNIT

CONTROL WIRING

TERMINAL BOX

R -

G -

Y -

0

-

W2-

E -

ro

^—

! =^00

INSTALL-

JUMPER

- R

• G

--------

Y

-

0

-E-

- -W3-

C -

-VI0-(HR1

--------^BLK-(

h

R2)

-0RN-(

h

R3

-BRN

ODT — Outdoor Thermostat
HR — Heater Relay

COOLING AND TWO-STAGE HEATING

(Unit equipped with 88EJ Electric Heater,

Emergency Heat, one Outdoor Thermostat)

THERMOSTAT

a

SUBBASE

(SEE BELOW)

50YQ UNIT

CONTROL WIRING

TERMINAL BOX

R -

-- R

G -

- G

Y -

— Y

0 -

-- 0

W2--

-^W2^:

E --

(EH^ j0DT2[^"U0DTl

■ - E —^

1 L

-|

-W3—^

c —

— C — -

L

-VI0-(HRI

I"LI

L

ehr

"

J

-■bRN-(HR3'

EHR
HR

ODT

— Emergency Heat Relay
— Heater Relay
— Outdoor Thermostat

COOLING AND TWO-STAGE HEATING

(Unit equipped with 88EJ Electric Heater,

Emergency Heat, no Outdoor Thermostats)

Fig. 8 — Control Connections

COOLING AND TWO-STAGE HEATING

(Unit equipped with 88EJ Electric Heater, Emergency

Heat Relay, two Outdoor Thermostats)

7 8 1