Carrier 58DH User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

T

Horizontal Attic Installation

— The Model 58DH

furnace can be installed horizontally on either the
left-hand or right-hand side. A typical attic installa­
tion is shown in Fig. 8.

NOfF.; For attic installations, use Type li or

I \|v- 1 \i in in.it^ii.il

CONSTRUCT WORKING PLATFORM

1. Place working platform in location where all

required furnace clearances are obtainable. See
Table 1.

2. Use materials in platform that can support in­

staller and service persons.

3. Secure platform to building joists.

INSTALL FURNACE

1. Position furnace in desired location.

2. Connect gas supply pipe. See Fig. 8 for typical

piping entry. It is important to install a sediment
trap in the gas pipe riser.

3. Connect supply and return air ducts.

a. Install accessory duct flange kit as shown in

Fig. 9.

b. Connect duct to furnace, using appropriate

fasteners for type of supply air duct being used.

c. Install accessory filter retainer kit before

connecting return air duct to furnace. See
Fig. 10 and Table 5. See note below.

d. Using appropriate fasteners for type of duct

being used, connect return air duct to furnace.

NOTE: For ease of servicing, a return air filter can
be installed in a common return air grille. Air

velocity rating must not exceed 300 fpm for dispos­
able filters. Air velocity through reusable-type filters

shall not exceed manufacturer’s recommendation.

4. Install 24 X 24 in. sheet metal shield on platform

in front of louvered control panel. See Fig. 8.

5. Proceed to Electrical Connections for wiring

information.

Fig. 10 — Horizontal Filter Arrangement

(See Table 5.)

Advertising