5. Slide piston out by inserting a small soft wire

thru metering hole (18-gage thermostat wire).

See that metering hole, sealing surface around
piston cones and fluted portion of piston are

,

not damaged.

I

6. Clean piston refrigerant metering hole.

7.

Replace

retainer

O-ring

before

reassembling

bypass type AccuRater™. Carrier O-ring part no.
is 99CC501052.

LIQUID

LINE

STRAINER

protects

AccuRater.

Made of wire mesh, it is located in the liquid line

inside indoor fan coil behind liquid line service
valve (Fig. 25). Liquid line is belled and sweat
connected where strainer is located. If strainer is
plugged, unsweat belled liquid line connection and

replace strainer.

MAINTENANCE

Lubrication

COMPRESSOR contains factory oil charge. Re­
place oil when lost. See Table 8 for oil recharge.

If necessary, refer to Carrier Standard Service Tech­

niques Manual, Chapter 1, page 1-21, for oil
recharging procedure. Use Carrier PP33-1, Texaco
Capella B or Suniso 3G oil.

OUTDOOR FAN MOTOR BEARINGS are pre­
lubricated for 3 years heavy duty or 5 years normal
duty. When lubrication is necessary, send motor to
authorized motor repair shop.

Outdoor Coil Cleaning Ensure power to unit is

shut off. Clean the outdoor coil with water at the

beginning of every cooling season or more often if

required. Use ordinary garden hose at a pressure

high enough to clean efficiently. For best results, un­

screw and remove unit top cover (grille).

Insert hose nozzle between fan blades and spray

coil fins from inside-to-outside the unit. If unit has
a double-row coil, loosen screws to separate coils,

pull outer row of coils away from inner row, and
flush dirt toward outside of both coils. Flush dirt

from basepan by spraying water thru top of unit.

Avoid splashing mud on coil or water on the fan
motor. Make sure that water drainage holes under
outdoor coil are not obstructed.

Outdoor Fan Position — Required fan position is
shown in Fig. 27. Adjust fan by loosening setscrews
and moving fan blades up or down.

FAN MOTOR REMOVAL

1. Shut off power to outdoor coil.

2. Remove unit top cover (grille). Open or remove

service door. Remove junction box cover.

3. Disconnect fan motor leads in line-voltage

section of junction box. See Fig. 24.

Fig. 27 — Outdoor Fan Position

4.

Remove fan from motor shaft by loosening

setscrews and pulling upward on fan hub.

5.

Remove bolt holding fan motor to motor

mounting bracket. Remove motor with wiring

thru top of unit.

To replace motor: place motor on self-positioning

motor mounting bracket and retighten bolt.

Before replacing metal fan, be sure rain shield

>(Fig. 27) is in place on motor shaft. Seal with

Permagum around hub to prevent entry of water

between hub and shaft.

Compatible Fitting Repair

LEAKING

MECHANICAL

CONNECTION

Frontseat outdoor section service valves and relieve
refrigerant

pressure

in

tubing

and

compressor

section.

Back

locknut

off

Carrier

Compatible

Fitting

onto

tube.

Cut

fitting

between

threads

and seal ring bead shown in Fig. 28. Remove tubing
section remaining in threaded portion of fitting.

Discard locknut.

Fig. 28 — Carrier Compatible Fitting

Clean, flux, and insert new tube end into remain­

ing portion of Carrier Compatible Fitting. Wrap

valve base (outdoor unit) in wet rag. Heat and apply

Tow-temperature solder (430 F).

LEAKING

SWEAT

CONNECTION

Frontseat

service

valves

and

relieve

refrigerant

pressure

in tubing. Clean and flux area around leak and apply

- low-temperature solder (430 F).

Evacuate or purge indoor fan coil, compressor

section and tubing system. Add refrigerant charge

(see charging instructions).

LEAKING

FLARE

CONNECTION

Cut

and

reflare 3/8-in. system liquid line.

17