1 kukm), Fig. 12—wiring diagram – Carrier 58DHL User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

cn

1 KUKM)

lA-TRANSKOUMKK. t>i'VACV->-IVAC

:>n-

iNDi CKH MciTOH m>sr-\ o

2K-KtL\v HKAi is'; m.uwKH {MHO Si’M s

<~

UKLAV CO(ll.!\<. HLUWI-H 11 MOl’I’I'l

dA-MUTOU INUK-i:»

3l>-MOTOM ni.owt.u

•lA-CAl'ACITOn mN

SK VALVb: GAS (RtDl N'DANT)

lin-nOARD I’ C (R RNACE COSTHOL)

l>C2-nOAnD I’ C (INDI CLR CONTROL)

6F-GLNKRATOR, Si'ARK (SOIJU STATL)
1>H SWITCH 1‘Iinr FIAMK NKNSING

SPOT

(740A)

--------------------FIELD WIRING {24VAC)

___ INI)I CTOHS ON <iCI (h ! RNAC

2ZZZZZZZZ CUNDI CTORS i IN iiC.’ {!N1>' CKH CONTROL MOARI)

(2> SCRKU PKHMINAI. HJR UKl.l) W IIUM.

7HI-SWrrCH, UMIT S. P. S. T. -N.C.

I/-I INCH UK CONM.Cl TLRMIN A 1.-

7H2-SWrrCH, DRAFT SAFEGUARD (S. P. S. T. - N.C. ) MANUAL RESET

7H3-SWITCH, AUXILIARY UMIT (S. P. S. T. - N.C, ) MANUAL RESET (WHEN USED)

7\-SUnCM FLCAV SENSING SPOT

!Hi-S\\ITCH. 1UXA\KH DOOR INTLRl.IX'K .'•I’Sr-N O

l ilH -CUNNKCTOR KIH.L (I I RNACL CONTROL HOARi>)

\*»IV> CUNNLCTOR U)GL (INIHCKR CT>NTROL HOARD-7 CKT.)

l'iH3-CONNKCTOR KDGK {INDI CLR tRlNTROL HOARD-2 CKT. )

DIH-l-CONNECTOR. I’ll.OT

HHW-KACTORY TKST POINTS (NOT FOR FIELD USE)

Uinii-CONNLCTOR I LOWKR MOTOR

tlC-IJNK n SIHLL (tiVKR TKMPLRATI RK) {1 REQD, ON UPFtOW * 3 REQD, ON

11B FUSE, IN LINE 2AMP (WHEN U8B|)

DOWNFLOW/HORIZONTAL FURNACE

UE-OROUND EQUIPMENT

RD

7P-PRESSURE SWITCH, N. ‘0.

6C3-LOCKOUT MODULE

TPl-TEST PCXNT

2. RELAY (2E) CONTACTS ARE HORHALLY CLOSED UNTIL 120VAC IS APPLIED TO FURNACE.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED MUST BE REPLACED, IT MUST BE REPWCED

WITH AWMC105 O' WIRE OR ITS EQUIVALENT.

i|. BLOWER TOTOR (3D) BAS A TKEWAL OVERLOAD SWITCH.
5. BLOWER MOTOR (3D) FACTORY SPEED SELECTIONS ARE FOR AVERAGE CONDITIONS. SEE

IHSTALLATIOH INSTRUCTIONS FOR DETAILS OH OPTIMUM SPEH) SELECTION. MOTOR MAY HAVE
3 OR A SPEED TAPS.

6. USE COPPER WIRE ONLY BETWEEN THE DISCONNECT SWITCH AND THE UNIT.
7. SYMBOLS ARE AN ELECTRICAL REPRESENTATION ONLY.
8. PRESSURE SWITCH (7P) IS USED FOR PROPWIE ONLY.
9. FUSIBLE LINK USAGE. 1 REW. ON UPFLOW S 3 REQD. ON DOWNFLOW HORIZONTAL FURNACE.

10. LOCKOUT MODULE (6C3) IS USED FOR PROPANE OR iOOZ SHUTOFF NATURAL GAS.
11. 2 AMP FUSE IN SECONDARY OF TRAKSF.FOR CANADIAN

UNITS ONLY.

12. FACTORY CONNECTED WHEN ACCESSORY NOT USED.__ ____ _

309260-401 Rev.

F

Fig. 12—Wiring Diagram