21

T O R E G U L A T E N E E D L E T H R E A D T E N S I O N

The tension on needle thread can be tested

only when presser foot is down.

The numerals “0 to 9”
on dial D, Fig. 23 in­

dicate different degrees

;y| of tension that can be

3o b t a i n e d. The num­

bers do not denote size
of thread or ounces of
tension.

J

'T

When tension has been

NeedLe I firead 1 ension

,

correctly set as de­

scribed on pages 23 and 24, note number at

indicator line G so that this setting may be
regained should the tension be altered for
special work.

To increase tension, turn thumb nut B
gradually to right (clockwise) until required

tension is obtained. Each higher number de­

notes increased tension.

To decrease tension, turn thumb nut B
gradually to left (counter-clockwise) until re­
quired tension is obtained. Each lower num­
ber denotes less tension.
The tension indicator G is marked with the

signs -f- and —, which indicate the direction
in which to turn the thumb nut B for more

or less tension.

T O R E G U L A T E B O B B I N T H R E A D T E N S I O N

The tension on bobbin thread is regulated by
screw AA, Fig. 24 which is nearest center of
tension spring on outside of bobbin case. To
increase tension, turn screw AA over to right.

To decrease tension, turn

this screw over to left.

^

When tension on bobbin
thread has been once prop­

erly adjusted, it is seldom

necessary to change it, as a
correct stitch can usually be
obtained by varying tension
on needle thread.

Fig. 24. Bobbin Thread Tension

22

Fig. 25. Needle Thread Tension Disassembled

T O R E M O V E A N D D I S A S S E M B L E N E 4 . E T H R E A D T E N S I O N

Turn thumb nut B to left (counter-clockwise) until ‘‘O” on
numbered dial stops at cente** bne on indicator G.

To separate pin C in thumb nut B from dial

D, press in dial, unscrew thumb nut and re­
move it. Then remove dial, stop washer E,
tension spring F, indicator G and tension
assembly H.

NOTE: It is not necessary to remove stud O
from machine to disassemble the thread ten­
sion. It is shown removed in Fig. 25, only

to illustrate the complete assembly.

Fig. 26. Tension Disc Assembly

T O R E A S S E M B L E A N D R E P L A C E N E E D L E T H R E A D T E N S I O N

Make sure that tension releasing pin J is in place in stud O.
Place two tension discs L with their convex faces together on
tension thread guide M, then pass eyelet N of thread take-up

spring under thread guide, having coils of spring above ten­
sion discs, as shown in Fig. 26.