Fuel filter, Air cleaner, Model 13037 – Troy-Bilt 13034 User Manual

Page 25: Carburetor, Battery, A warning, Models 13034, fio 6-8 13035 & 13036, Maintenance (continued)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Maintenance (continued)

Fig. 6-6

Fuel Filter

Air Cleaner

Fig. 6-7

Model 13037

• Wash foam pre-cleaner (A) in liquid
detergent and warm water. Squeeze dry in
a clean cloth.

• Saturate foam pre-cleaner in clean

engine oil. Wrap in clean, absorbent cloth
and squeeze to remove a//excess engine

oil.

• Clean or replace paper cartridge (B) if

necessary. To clean: Tap gently against a

flat surface. If very dirty, replace or wash

in non-sudsing detergent and warm water.

Rinse thoroughly with clean water from

inside out. Thoroughly air dry.

• Reassemble air cleaner components.
Tighten knobs (D) securely. Clip cover

assembly (E) onto air cleaner body.

Carburetor

The carburetor is adjusted at the factory.

It should not need to be reset. If a black

exhaust is noted, check the air cleaner

first. An over-rich mixture is usually

caused by a poorly serviced or clogged air

cleaner element, not an improperly

adjusted carburetor. If readjustment is

necessary, refer to engine manual or

contact your dealer for servicing.

Battery

A

WARNING

Air Cleaner

Models 13034,

Fio 6-8

13035 & 13036

ELECTROLYTE CAN CAUSE SEVERE
BURNS AND BLINDNESS. ALWAYS
WEAR SAFETY GOGGLES WHEN
WORKING AROUND BAHERIES.

Keep cables and terminals clean. If cables
are corroded, clean them. After cleaning,
apply a light coat of petroleum jelly or

grease to terminals and bolts. ALWAYS
CONNECT THE NEGATIVE (-) TERMINAL
LAST.

Electrolyte should be level with bottom

edge of cell. See Figure 6-9. Fill with
distilled water only. Operating unit with

battery electrolyte level too low can

damage battery. If rapid loss of electrolyte

is observed, or if you experience electrical
or starting problems, contact your local
dealer.

Remove battery cables before removing

battery. Remove negative (-) cable first,

then positive (+) cable. Always check

polarity of battery terminals. Make sure

battery is not reversed. Negative (-) cable
is ground.

CHARGING: Remove filler caps. Charge at
2 amps until specific gravity reading is
1.265 to 1.275. Charging may take several
hours.

Fill to here

Fig 6-9 Battery Electrolyte Level