MAINTENANCE

Section 3 - Maintenance

Series QP55-C Recreational Vehicle Generator

3.13 OUT OF SERVICE PROCEDURE

♦ 3.15.1 REMOVAL FROM SERVICE___________________

If you cannot exercise the generator every seven

days, and it is to be out of service longer than 30
days, prepare the generator for storage as follows:

1. Start the engine and let it warm up.

2.

Close the fuel shutoff valve in the fuel supply

line and allow the unit to shut down.

3.

While the engine is still warm from running,

drain the oil completely. Refill the crankcase
with SAE lOW-30 oil having API classification
"For Service SF.”

4.

Attach a tag to the engine indicating the viscos­

ity and classification of the oil in the crankcase.

5.

Remove the spark plug and pour two or three

tablespoons of clean, fresh engine oil into the
spark

plug

threaded

openings.

Reinstall

and

tighten the spark plug.

6.

Remove the battery and store it in a cool, dry

room on a wooden board. Never store the bat­
tery on any concrete or earthen floor.

7. Clean and wipe the entire generator.

♦ 3.13.2 RETURN TO SERVICE

To return the unit to service after storage, proceed

as follows:

1. Check the tag on the engine for oil viscosity and

classification. Verify that the correct recom­
mended oil is used in the engine (see Section

1.5.4, Page 6). If necessary, drain and refill with

the proper oil.

2.

Check the state of the battery. FUl aU cells of

unsealed batteries to the proper level with distilled
water. DO NOT USE TAP WATER IN THE BAT­

TERY. Recharge the battery to 100 percent state of

charge, or, if defective, replace the battery.

3. Clean and wipe the entire generator.
4.

Reconnect the battery. Observe battery polarity.

Damage may occur if the battery is connected
incorrectly.

5.

Turn OFF all electrical loads. Add fuel if neces­

sary and then start the engine.

6. Allow the unit to warm up thoroughly.
7.

Apply electrical loads to at least 50 percent of

the unit’s rated wattage capacity.

8.

When the engine is thoroughly warmed up,

shut it down.

9. Your generator is now ready for service.