INSTALLATION

z?

Section 2 - Installation

Series QP55-G Recreational Vehicle Generator

2.7

BATTERY INSTALLATION

2.7.1 RECOMMENDED BATTERY___________________

Install

a

battery

that

meets

the

following

requirements:

The battery must be a 12-volt, automotive type

storage battery.

For prevailing ambient temperatures above 32° F

(0° C), use a batteiy rated 70 amp-hours and
capable of delivering 400 cold-cranking amperes.

For prevailing ambient temperatures below 32° F

(0° C), use a battery rated 95 amp-hours and

capable of delivering 400 cold-cranking amperes.

NOTE:

If the battery is to be used to power other vehi­
cle accessories, as well as start the generator,

you may need a battery with a larger capacity.

2.7.2 BATTERY CABLES

Using batteiy cables that are too long or too small in
diameter may cause a drop in voltage, which causes
starting problems. For the best cold weather starting,
the voltage drop between batteiy terminals and the
generator connection point should not exceed 0.12

volts per 100 amperes of cranking current.

These

generators

are

rated

at

about

100

DC

amperes of cranking current.

Select battery cables based on (a) cable length and (b)
prevailing

ambient

temperatures.

Generally,

the

longer the cable and the colder the weather, the larg­
er the cable size must be, as shown in the chart.

CABLE LENGTH
in Feet (meters)

CABLE SIZE

0 to 10 (0 to 3)

2*

11 to 15 (3.4 to 4.5)

0

16 to 20 (4.5 to 6)

000

♦ 2.7.3 BATTERY CABLE CONNECTIONS

1. Connect the battery cable from the battery post

or terminal indicated by a POSITIVE, POS or (+)
to the lug on the starter contactor (Figure 2.19).

NOTE:

Check to be sure the battery cable hoot for the
starter cable has been

installed.

2

.

3.

Connect the battery cable from the battery post
indicated by a NEGATIVE, NEG or (-) to the

frame ground connection (Figure 2.19).
Connect cables so the connectors are clean
and tight.

Figure 2.19 - Connecting Battery Cables

SIDE VIEW OF GENERATOR

♦ For warm

weather, use No.

2

cable up to

20

feet.

- ♦ 2.7.4 BATTERY COMPARTMENT ____________________

Install the generator battery in its own, vented com­
partment.

Place

the

batteiy

compartment

away

from any source of heat, sparks or flame.

Provide ventilation openings in the batteiy com­
partment. The minimum size of openings should be
2 square inches at the top of the compartment.
Mount the battery on a strong, rigid supporting
structure, where leaks and spills of battery fluid

will not cause damage.

32 Generac® Power Systems, Inc.