Section 2 - Operation

Series QP55-G Recreational Vehicle Generator

OPERATION

2.1

GENERATOR CONTROL PANEL

The following features are mounted on the genera­

tor control panel (Figure 2.1):

Figure 2.1 - Generator Control Panel

FUSE MAIIV

START ISA BREAKER

♦ 2.1.1 FUEL PRIMER

Before starting a cold engine (if it has not been
started in more than two weeks), you must press
this switch for approximately five seconds to bring
fuel from the tank to the carburetor or fuel regula­
tor (LP). This rocker type switch springs back into
its original position when you release it.

♦ 2.1.2 START/STOP SWITCH

To crank and start the engine, hold this switch in

the START position. Release the switch when the
engine starts. To stop an operating engine, press
and hold the switch in the STOP position until the
engine shuts off. The switch center position is the
RUN position.

♦ 2.1.3 FUSE

The fuse protects the engine’s DC control circuit

against electrical overload. If the fuse element has
melted open due to overloading, the engine cannot

be cranked. If you must replace the fuse, use only
an identical replacement.

4 2.1.4 MAIN BREAKER

The main breaker protects the generator’s AC out­

put

circuit

against

overload

or

exceeding

wattage/amperage capacity.

2.2

OPTIONAL REMOTE

START/STOP PANELS

♦ 2.2.1 REMOTE PANEL PLUG-IN RECEPTACLE

A plug-in receptacle (Figure 2.2) is provided on the

generator set, above the muffler enclosure. Use this
receptacle to connect an optional remote-mounted
start/stop panel to the generator. Installation of
such a panel will permit you to start and stop the
generator

engine

from

any

convenient

location

Inside the vehicle.

Figure 2.2

Remote Panel Plug-in Receptacle

WIRE #18
(STOP)

WIRE #14

(ENGINE RUN
SIGNAL)

WIRE #0
(GROUND)

WIRE #17
(CRANK)

♦ 2.2.2 MODELS 4057-0 AND 4184-0___________________

These remote panels mount a rocker type switch, a

“Generator Run” lamp and an hourmeter (Figure

2.3). The hourmeter should be used in conjunction

with the maintenance operations found in Part I of
this manual.

Figure 2.3

Models 4057-0 and 4184-0

Remote Panel