SECTION 2.2

DIAGNOSTIC TESTS

TEST 1 - 1 5 AMPFUSE

Remove and visually inspect the 15

Amp Fuse. Replace, if Fuse element
has melted. A more thorough check

may be made with a Volt-Ohm-Milli-

ammeter, as follows

1. )-Set VOM to ”+DC” and to "Rxl”

scale.
2. )-Connect meter test probes and

”Zero’^ the meter.

3. )-Connect meter test probes to

Fuse ends. Meter needle should

swing upscale to ’^0” ohms (continu­
ity). If meter needle does not move

upscale, replace the Fuse.

RESULTS:-Fuse tests bad............

Fuse tests good....... .

.Install new 15 Amp Fuse
.Continue tests

TEST 2-BATTERY

Check Battery condition, as well as

the condition, cleanliness and sec­

urity of battery cables and connec­

tions .

RESULTS:-Battery, cables or connections,

check bad

Battery, cables or connections,

check good

.Recharge or replace de­

fective Battery. Repair,
clean or replace defect­
ive cables or connection

.Continue tests

2.2-1