TEST 12- IGNITION MODULE

Unplug the Ignition Module from

its receptacle on the side of the
stator can. Carefully inspect mo­
dule and receptacle pins for. dam­
age, bending or "pushing out"

from their retainers. Plug in a
known good "shop" module and
check for normal sparking at the

spark plug.

Ignition

Module

Ignition Module

Receptacle

RESULTS:- Ignition Module tests good................ Continue tests

Ignition Module tests bad................ ........Replace

TEST 13- IGNITION STATOR

A. )-Trig;g£r Coil:- Set VOM to "+DC"

and to "Rxl" scale. Zero the meter.

On the DC Control Board, unplug the

connector plug from its receptacle
to prevent interaction. Also unplug
the Ignition Module from its recep­
tacle. Insert one meter test probe

into Pin No. 3 of the Ignition Mod­

ule Receptacle. Connect tha remain­

ing test probe to frame ground. The

meter needle should swing upscale

and read Trigger Coil resistance (a-

bout 7 Ohms),

RESULTS:- Meter needle does not move.

Trigger

Coil

Meter needle swings upscale,

and indicates approximately

7 Ohms resistance

.Check Wire No. 25 between

Ignition Module receptacle

and Ignition Stator for an
"open" condition. If Wire

No. 25 is good, replace

Ignition Stator

.Continue checks

B.)- Charge Coil:- Set VOM to "+DC" and to "RxlO" scale, then zero the
meter. Insert one meter test probe into Pin No, 2 of the Ignition Mod­
ule receptacle. Connect the remaining test probe to frame ground. The

meter needle should swing upscale.and indicaie approximately 250 Ohms

resistance.

2.2-6