• Burner Fan/Motor

The combustion air is produced by a 6-inch diameter by 2-1/2-inch deep squirrel cage fan attached to a
3/4 hp, 3,600 rpm motor. The motor must spin counterclockwise as viewed from the rear of the motor.

Combustion Air Lint Filter

The combustion air lint filter is made of a fine mesh stainless steel screen which must be cleaned
regularly. This screen prevents any lint from entering the burner box.

Combustion Air Damper

To produce the required combustion airflow, this damper can be adjusted. Remove the lint screen to get
access to the damper. Moving the damper closer to the blower inlet opening will reduce the combustion

airflow, and moving it away from the blower inlet opening will increase the airflow. To measure the
combustion airflow, attach a manometer to the air pressure tap on the burner box. The air pressure
should measure 1.25 to 15 inches water column.

QAS PIPING

; COHBUSTON

' Aft SMTCH

IMET

MANUAL

SHUT OFF

VALVE

MAN0638