American Dryer Corp. AD-400 User Manual
Page 50
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

J
Safety Device
Location
Function
Computer Display
Message
Result Of Tripping
Load Door Switch
Left side of load door
In^es dryer load doors
are closed
"DOOR OPEN," Dryer
will not run
Dryer will not run
Unload door switch
Right side of unload doorInsures dryer unload
doors are closed
"DOOR OPEN," Dryer
will not run
Tilting Switches
Top left side of base
module
Insures dryer is level
"LEVEL FAULT," Dryer
will not run
Dryer will not run
Drum Rotation Sensor
Left side of tumbler
section
Insures tumbler is
rotating
"DRUM FAULT," Slops
heat only
Stop» heat only
Lint chamber air
pressure switch
Left side of base
Insures proper air flow
through dryer
"AIR FAULT," Stops
heat only
Stops heat only
Burner Fan Air Flow
Switch (Gas Dryers
Only)
Center of heater section Insures proper
combustion air flow into
the burner box
"HEATER FAULT,"
Stops heat only
Stops heat only
HI/LO Gas Pressure
Switch (Gas Dryers
Only)
Lower left of heater
section
Insures proper gas
supply pressure for
adequate ignition
"GAS FAULT," Stops
heat oiUy
Stops heat only
Lint Screen Mechanism
Switch
Front of base
Insures that chain is not
loose or broken
"SCREEN FAULT,"
Dryer will not run
Dryer will not run
Heat Reclaimer Damper
Switch
Right side of heater
Insures that the heat
reclaimer damper is
either opened or closed
Input LED #13 of the
PLCisoff
None
Heater Door Access
Door Switches
Inside heater section
Insures that access doors
are closed
"DOOR OPEN," Dryer
will not run
Dryer will not run
Exhaust Air Temp
Control Sensor
Inside burner section
exhaust duct
Monitors tumbler
exhaust air temp
"EXHAUST DSFL,"
Stops the heat only
Stops heat only
Exhaust Air Hi Temp
Safety Sensor
Inside burner section
exhaust duct
Monitors tumbler
exhaust air temp
"Hl-TEMPFAULr
Stops heat only
Intake Air Temp Control
Sensor
Top right of tumbler
section
Monitors tumbler air
intake temp
"INTAKE DSFL," Stops
the heat oiUy
Stops heat only
Intake Air Hi Temp
Safety Sensor
Top right of tumbler
section
Monitors tumbler air
intake temp
"HI-TEMP FAULT,"
Stops the heat only
Stops heat only
Burner Hi Limit Safety
Sensor (Gas Dryers Only)
Top of burner section
Monitors air temp above
the burner box
"HI-TEMP FAULT,"
Stops the heat only
Stops heat only
Sprinkler Control Safety
Sensor
Top right of tumbler
section
Opens sprinkler system
water valve on hi-temp
condition
Orange sprinkler pilot
light comes on. Alarm
horn soimds
Opsns the sprinkler
water valve and piowers
down the whole dryer
48