American Dryer Corp. AD-400 User Manual

Page 50

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

J

Safety Device

Location

Function

Computer Display

Message

Result Of Tripping

Load Door Switch

Left side of load door

In^es dryer load doors
are closed

"DOOR OPEN," Dryer
will not run

Dryer will not run

Unload door switch

Right side of unload doorInsures dryer unload

doors are closed

"DOOR OPEN," Dryer
will not run

Tilting Switches

Top left side of base
module

Insures dryer is level

"LEVEL FAULT," Dryer
will not run

Dryer will not run

Drum Rotation Sensor

Left side of tumbler
section

Insures tumbler is
rotating

"DRUM FAULT," Slops

heat only

Stop» heat only

Lint chamber air
pressure switch

Left side of base

Insures proper air flow
through dryer

"AIR FAULT," Stops

heat only

Stops heat only

Burner Fan Air Flow

Switch (Gas Dryers

Only)

Center of heater section Insures proper

combustion air flow into

the burner box

"HEATER FAULT,"

Stops heat only

Stops heat only

HI/LO Gas Pressure
Switch (Gas Dryers
Only)

Lower left of heater
section

Insures proper gas
supply pressure for
adequate ignition

"GAS FAULT," Stops

heat oiUy

Stops heat only

Lint Screen Mechanism
Switch

Front of base

Insures that chain is not
loose or broken

"SCREEN FAULT,"
Dryer will not run

Dryer will not run

Heat Reclaimer Damper
Switch

Right side of heater

Insures that the heat
reclaimer damper is
either opened or closed

Input LED #13 of the
PLCisoff

None

Heater Door Access
Door Switches

Inside heater section

Insures that access doors
are closed

"DOOR OPEN," Dryer

will not run

Dryer will not run

Exhaust Air Temp
Control Sensor

Inside burner section
exhaust duct

Monitors tumbler
exhaust air temp

"EXHAUST DSFL,"

Stops the heat only

Stops heat only

Exhaust Air Hi Temp
Safety Sensor

Inside burner section
exhaust duct

Monitors tumbler
exhaust air temp

"Hl-TEMPFAULr

Stops heat only

Intake Air Temp Control
Sensor

Top right of tumbler
section

Monitors tumbler air
intake temp

"INTAKE DSFL," Stops
the heat oiUy

Stops heat only

Intake Air Hi Temp
Safety Sensor

Top right of tumbler
section

Monitors tumbler air
intake temp

"HI-TEMP FAULT,"

Stops the heat only

Stops heat only

Burner Hi Limit Safety

Sensor (Gas Dryers Only)

Top of burner section

Monitors air temp above
the burner box

"HI-TEMP FAULT,"

Stops the heat only

Stops heat only

Sprinkler Control Safety
Sensor

Top right of tumbler
section

Opens sprinkler system

water valve on hi-temp

condition

Orange sprinkler pilot
light comes on. Alarm
horn soimds

Opsns the sprinkler

water valve and piowers

down the whole dryer

48

Advertising