1.

STOP! Read the safety information,
column 2.

2.

Make sure manual shutoff valve is
fully open.

3.

Press in and turn control knob clock-
wise

Clockwise

to the OFF position.

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open damper or window to vent
smell. This will only last a few hours.

FOR YOUR

SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

LIGHTING

INSTRUCTIONS

WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you oper-
ate heater with doors closed,
heat buildup inside fireplace will
cause glass to burst. Also if
fireplace opening has vents at
the bottom, you must open the
vents before operating heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

The thermostat control knob can be set to
any comfort level between Hi and Lo.
The thermostat will gradually modulate
the heat output and flame height from
higher to lower settings, or pilot, in order
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

Note:

Selecting the Hi setting with the

control knob will cause the burners to
remain fully on, without modulating down
in most cases.

Variable Manually-Controlled
Models

OPERATING
HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise

to the OFF position.

Shutting Off Burners Only (pilot
stays lit)

1.

Turn control knob clockwise

to the PILOT position.

THERMOSTAT

CONTROL OPERATION

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 14.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 14.

Note:

Home owners generally prefer to

operate their heater with the chimney
damper closed. This will put all the heat
into the room. However, there may be
times you will desire the full flames of the
High heat setting but will find the heat
output excessive. You can open the chim-
ney damper (if you have one) fully or
partially to release some of the heat.

WARNING: Damper handle

will be hot if heater has been
running.

Continued

Figure 22 - Control Knob and Ignitor But-
ton Location

Control Knob

Ignitor Button

Advertising