UNVENTED NATURAL GAS LOG HEATER

103424

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
Technical Service web site at

www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

Model

CGG3324NT

CGG2618N

CGG3324N

CGG3630N

Btu (Variable)

20,000/33,000

16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Natural Gas Only

Natural Gas Only

Natural Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Piezo

Piezo

Pressure

3.4" W.C.

3.4" W.C.

3.4" W.C.

3.4" W.C.

Inlet Gas Pressure (in. of water)
Maximum

10.5"

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

5"

* For purpose of input adjustment

Shipping Weight

38 lbs.

36 lbs.

38 lbs.

40 lbs.

SPECIFICATIONS

ACCESSORIES

Purchase these heater accessories from your
local dealer. If they can not supply these
accessories, call DESA International’s Parts
Department at 1-800-972-7879 for infor-
mation. You can also write to the address
listed on the back page of this manual.

MANUAL SHUTOFF VALVE
GA5010

For all models. Manual shutoff valve with 1/8"
NPT tap. Fits 1/2" NPT pipe.

FIREPLACE HOOD

Black - GA6050
Brass - GA6052
Antique Brass - GA6053

For all models. Helps deflect heat away
from mantel or wall above fireplace.

LAVA ROCK - GA6060
(Not Shown)

For all models. Order when additional rock
is desired. (3 lb. bag)

DAMPER CLAMP - GA6080
(Not Shown)

For variably controlled models. Permanently
opens chimney flue damper for vented op-
eration.