Unvented natural gas log heater, Inspecting burners, Operating heater – Desa CGG2618N User Manual

Page 16: Continued

Advertising
background image

16

UNVENTED NATURAL GAS LOG HEATER

103424

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern.
Figure 25 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 25

• turn heater off (see To Turn Off Gas to

Appliance [Thermostat-Controlled Mod-
els] page 15 or [Variable Manually-Con-
trolled Models] page 16)

• see Troubleshooting, pages 18 through 20

Thermocouple

Pilot Burner

Figure 24 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot Flame Pattern

Figure 23 - Pilot

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, page 15. If you don’t smell
gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise

C-clockwise

to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 22,
page 15).
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.

6.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

If pilot does not light, contact

a qualified service person or gas sup-
plier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
, column 3.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7, pages 15 and 16.

8.

Push in and turn control knob coun-
terclockwise

C-clockwise

to the HIGH

position. Both burners should light.
Set control knob to desired setting.

Thermocouple

Ignitor Electrode

Pilot Burner

OPERATING
HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Press in and turn control knob clock-
wise

Clockwise

to the HIGH position.

2.

Turn the control knob clockwise

Clockwise

to the PILOT position.

3.

Press in control knob and turn clock-
wise

Clockwise

to the OFF Position.

Shutting Off Burners Only (pilot
stays lit)

1.

Turn the control knob clockwise

Clockwise

to the HIGH position.

2.

Press in and turn control knob clock-
wise

Clockwise

to the pilot position.

WARNING: Do not operate

heater between pilot and high.

CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

VARIABLE CONTROL

OPERATION

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, pages 15 and 16.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, column 1.

The variable control valve can be set to
any heat setting and flame height desired
between high and low by simply turning
the control knob until that setting is at-
tained. Even the lowest setting provides
realistic flames and glowing embers from
two burners. Selecting higher settings pro-
duces greater heat output. This results in
increased heating comfort.