9

103424

OWNER’S MANUAL

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

12"

8"

(A)

20"

14"

24

1/2

"

16

3/4

"

27

1/2

"

18

1/2

"

30"

20"

All minimum
distances are
in inches

Log Set
24"/30" Models

18" Model

2

1

/2

"

6"

8"

10"

Figure 6 - Minimum Mantel Clearances Without Using Hood

MANTEL CLEARANCES

In addition to meeting noncombustible ma-
terial clearances, you must also meet re-
quired clearances between fireplace open-
ing and mantel shelf. If you do not meet the
minimum clearances listed in Figure 6, you
will need a hood.

Determining Minimum Mantel
Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).

Determining Minimum Mantel
Clearance When Using a Hood

If minimum clearances in Figure 6 are not
met, you must have a hood. Follow mini-
mum clearances shown in Figure 7 when
using hood.

Mantel Shelf

INSTALLATION

Continued

Figure 7 - Minimum Mantel Clearances When Using Hood

Mantel Shelf

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Sets

18", 24",
& 30" Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

NOTICE: If your installation does
not meet the minimum clearances
shown in Figure 7, you must do
one of the following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

14"
Min.

Combustible
Material

Noncombustible
Material

Hearth

5"
Min.

Combustible
Material

Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring

Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level

FLOOR CLEARANCES

A. If installing appliance on the floor level,

you must maintain the minimum
distance of 14" to combustibles (see
Figure 8).

B. If combustible materials are less than

14" from the fireplace, you must install
appliance at least 5" above the
combustible flooring (see Figure 9).

Continued

Hood
(GA6050, GA6052,
or GA6053)