DELETING THE APPLICATION PROGRAM


This procedure allows deleting application programs developed with
DS for Formula™. If you want to delete programs provided or
developed by EasyGen™, refer to chapter 6 of the EasyGen™
manual.

NOTE

The following procedure causes data to be
deleted even if not completed.


If the application program must be cancelled follow the instructions
below:

1- Press the <SCAN> key and the protected reset button at the

same time; the display will show:

PROGRAM

ERASE?

= No Yes =

NOTE

If you do not want to delete the application
program, press the {▲} or wait about 25 seconds.

2- To continue with the deletion, press the ▼ key; after a few

seconds, the display will show:

BOOTSTRAP-

LOADER v6r1

ErasPrgFlash


3- Once the deletion procedure is completed, the terminal is

ready to receive a new application program. This is installed
using the methods described in the DS for Formula™ manual.