3. Check all joints from propane/LP supply tank

to equipment shutoff valve for propane/LP gas

(see Figure 16) or from gas meter to equipment

shutoff valve for natural gas (see Figure 17).

Apply noncorrosive leak detection fluid to gas

joints. Bubbles forming show a leak.

4. Correct all leaks at once.

INSTALLATION

Continued

Figure 15 - Equipment Shutoff Valve

Equipment
Shutoff Valve

Figure 16 - Checking Gas Joints

Propane/LP Tank

Equipment
Shutoff Valve

Valve Location

Figure 17 - Checking Gas Joints

Gas Meter

Open

Closed

Equipment
Shutoff Valve

Valve Location

INSTALLING OPTIONAL REMOTE
ACCESSORIES

Installing Remote Receiver
Remote control accessories are available sepa-

rately (see Accessories, page 29).
1. If unit is already installed in fireplace, continue

with these instructions. If unit has not been

installed in fireplace, go to step 6 and continue

installation of remote accessory.

WARNING: Turn off heater

and let cool before handling any

part of heater. Make sure gas is

turned of to unit.

2. Carefully remove logs and set aside.
3. Locate mounting screws on sides of heater

base assembly and remove screws. Set screws

aside for reinstallation.

4. Disconnect gas line from heater base as shown

in Figure 11, page 13.

WARNING: A qualified ser-

vice person must connect and

disconnect gas to heater. Follow

all local codes.

5. Remove heater base from fireplace.
6. Install receiver bracket to base with phillips

screws provided in hardware kit as shown in

Figure 18.

7. Disconnect jumper wire from control valve at

TPTH and TH locations (see Figure 19).

Figure 19 - Disconnecting Jumper Wire

from Control Valve

Jumper
Wire

Control
Valve

Figure 18 - Installing Remote Receiver

Bracket

Remote
Receiver
Bracket

Phillips Screws

Advertising